SOC Follow-Up Report – System-wide Pack Condition
DURATION OF EVENT
A system-wide Strained Operating Condition (“SOC”) for a Pack condition was declared by EPNG as follows:
Effective: Gas Day November 3, 2025
Imbalance Threshold: 5%
AFFECTED AREA(S)/LOCATION(S)
All shippers system-wide were subject to the requirements of the SOC declaration.
TIMELINE
[November 3, 2025, 7:57 am Mountain Standard Time (MST)] EPNG declared a system-wide SOC for a Pack condition effective Gas Day November 3, 2025, with the imbalance threshold set at 5% (Critical Notice No. 626627).
[November 4, 2025, 6:39 am MST] EPNG lifted the subject system-wide SOC effective Gas Day November 4, 2025 (Critical Notice No. 626636).
APPLICABLE OPERATING CONDITIONS
Monday, November 3, 2025
- EPNG system linepack started the Gas Day at 8,197 MMcf, which was an increase of 221 MMcf compared to the previous Gas Day.
- At 7:57 am MST, EPNG declared a system-wide SOC for a Pack condition (Notice No. 626627) effective Gas Day November 3, 2025. The EPNG system was experiencing a high linepack condition due to receipts in excess of scheduled quantities and deliveries below scheduled quantities.
- Washington Ranch was on full injection, averaging 96 MMcf.
Tuesday, November 4, 2025
- EPNG system linepack started the Gas Day at 8,009 MMcf, which was a decrease of 187 MMcf compared to the previous Gas Day.
- At 6:39 am MST, EPNG lifted the system-wide SOC for Pack condition (Notice No. 626636) effective Gas Day November 4, 2025. Customer response was sufficient to decrease EPNG's linepack to acceptable levels.
- Washington Ranch was on maximum injection, averaging 95 MMcf.
ACTIONS TAKEN BY EPNG AND SHIPPERS
The following actions were taken:
1. EPNG declared a system-wide SOC for a Pack condition on November 3, 2025, at 7:57 am MST. The system-wide SOC was in effect for Gas Day November 3, 2025, only.
2. After EPNG declared the system-wide SOC, customers took corrective actions to align their scheduled supplies with their actual deliveries.