Effective Evening Cycle (9:00) for the gas day of Saturday, October 10, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 ON THE 500 lINE FROM STA 527 TO STA 542 FOR OVERTAKES from the system OR UNDERDELIVERieS into the system FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
ofo daily critical day 1 for all areas east of sta 219 for overdeliveries into the system or undertakes out of the system for all lmpa, sa acting as balancing parties and lmma balancing parties
METER RESTRICTIONS
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through 100% of SOP increases due to operational concerns; 25,000 Dths
· UGIAPP/TGP Farmer Brothers Columbia Receipt Meter (Pin 53950) - through approx 8% of IT increases due to nominations in excess of operational capacity; 4,350 Dths
· LSTOCKNG/TGP Wyalusing Sales Bradfo Delivery Meter (Pin 420652) - through 100% of IT increases due to nominations in excess of operational capacity; 1,969 Dths
SEGMENT RESTRICTIONS
· STA 534 South Of Pool (Segment 530 BH) - through 100% of SOP increases due to operational concerns; 4,305 Dths
· Pemex Lateral (Segment 492 FH) - through approx 7% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 20,037 Dths
· STA 1 (Segment 101 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 18,054 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 190 Dths
· MLV 524 (Segment 524 FH) - through PIP increases due to force majeure
· STA 110 South (Segment 187 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 204 (Segment 204 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 401,739 Dths
· MLV 314 East (Segment 314 BH) - through approx 67% of SOP increases due to nominations in excess of operational capacity; 154,334 Dths
· STA 315 (Segment 315 BH) - through approx 65% of SOP increases due to nominations in excess of operational capacity; 214,617 Dths
· STA 317 (Segment 317 BH) - through approx 67% of SOP increases due to nominations in excess of operational capacity; 125,013 Dths
· STA 321 (Segment 321 FH) - through approx 70% of SOP increases due to nominations in excess of operational capacity; 229,761 Dths
· MLV 330 (Segment 324 FH) - through approx 43% of SOP increases due to nominations in excess of operational capacity; 65,069 Dths
· STA 224 (Segment 224 FH) - through approx 96% of SOP increases due to nominations in excess of operational capacity; 116,064 Dths
· STA 313 Hcg - Z4 Hc (Segment 399 BH) - through 100% of IT increases due to force majeure; 42,781 Dths
· STA 313Hcg - Z4 Hc (Segment 399 FH) - through PIP increases due to force majeure
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 130,623 Dths
LINEPACK RESTRICTIONS
PAYBACK NOMINATIONS WILL BE EVALUATED AT EACH CYCLE AND SCHEDULED ONLY IF OPERATIONALLY FEASIBLE.
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD or PAL-AO services
Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under FS-PA storage service only with partner approvals.
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.