Effective Timely Cycle (9:00) for the gas day of Friday, October 09, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 ON THE 500 lINE FROM STA 527 TO STA 542 FOR OVERTAKES from the system OR UNDERDELIVERieS into the system FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
ofo daily critical day 1 for all areas east of sta 219 for overdeliveries into the system or undertakes out of the system for all lmpa, sa acting as balancing parties and lmma balancing parties
METER RESTRICTIONS
· FGT/TGP Carnes Mississippi Stone Delivery Meter (Pin 420366) - through 100% of SIPps due to operational concerns; 10,000 Dths
· WHISTLEP/TGP Whistle Receipt Nueces Receipt Meter (Pin 54847) - through approx 74% of SA due to nominations in excess of operational capacity; 97,052 Dths
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through 100% of IT due to operational concerns; 32,511 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 43% of SOP due to operational concerns; 19,320 Dths
· GULFSTH/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through 100% of SOP due to operational concerns; 100 Dths
· TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 5,000 Dths
· LSTOCKNG/TGP Wyalusing Sales Bradfo Delivery Meter (Pin 420652) - through approx 69% of IT due to nominations in excess of operational capacity; 18,812 Dths
SEGMENT RESTRICTIONS
· Bay Springs (Segment 5420 FH) - through 100% of SOP due to operational concerns; 500 Dths
· STA 534 South Of Pool (Segment 530 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 20,864 Dths
· MLV 509 Muskrat Line (Segment 515 BH) - through approx 11% of IT due to nominations in excess of operational capacity; 2,067 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 190 Dths
· MLV 524 (Segment 524 FH) - into PIP due to force majeure
· STA 204 (Segment 204 BH) - through 100% of IT due to scheduled maintenance and nominations in excess of operational capacity; 2,077 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to nominations in excess of operational capacity; 401,739 Dths
· MLV 314 East (Segment 314 BH) - through approx 81% of SOP due to nominations in excess of operational capacity; 314,725 Dths
· STA 315 (Segment 315 BH) - through approx 86% of SOP due to nominations in excess of operational capacity; 424,184 Dths
· STA 317 (Segment 317 BH) - through approx 45% of SOP due to nominations in excess of operational capacity; 48,452 Dths
· STA 321 (Segment 321 FH) - through approx 40% of SOP due to nominations in excess of operational capacity; 415,533 Dths
· MLV 330 (Segment 324 FH) - through approx 25% of SOP due to nominations in excess of operational capacity; 165,032 Dths
· MLV 355 (Segment 355 BH) - through 100% of SOP due to operational concerns; 5,437 Dths
· STA 224 (Segment 224 BH) - through approx 93% of IT due to nominations in excess of operational capacity; 616,602 Dths
· STA 313 Hcg - Z4 Hc (Segment 399 BH) - through 100% of SOP due to force majeure; 3 Dths
· STA 313Hcg - Z4 Hc (Segment 399 FH) - into PIP due to force majeure
· STA 245 (Segment 245 FH) - through approx 51% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 314,399 Dths
· STA 249 (Segment 249 FH) - through approx 26% of SOP due to nominations in excess of operational capacity; 124,059 Dths
· MLV 273 (Segment 284 FH) - through approx 80% of SOP due to nominations in excess of operational capacity; 212,342 Dths
LINEPACK RESTRICTIONS
PAYBACK NOMINATIONS WILL BE EVALUATED AT EACH CYCLE AND SCHEDULED ONLY IF OPERATIONALLY FEASIBLE.
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD or PAL-AO services
Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under FS-PA storage service only with partner approvals.
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.