Effective Intraday 1 Cycle (14:00) for the gas day of Sunday, September 06, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 ON THE 500 lINE FROM STA 527 TO STA 542 FOR OVERTAKES from the system OR UNDERDELIVERieS into the system FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 219 FOR OVERDELIEVERIES INTO THE SYSTEM OR UNDERTAKES OUT OF THE SYSTEM FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
METER RESTRICTIONS
· TGP/SNG Toca Exchange St Bernard Delivery Meter (Pin 420556) - through 100% of IT increases due to operational concerns; 17 Dths
· ETNG/TGP East Lobelville Tn Perry Receipt Meter (Pin 420042) - through approx 84% of SOP increases receipts due to displacement gas unavailable for backhaul; 26,800 Dths
· Greenbrier Tn 2 (Dual) Receipt Meter (Pin 420289) - through approx 80% of SIPss increases receipts due to displacement gas unavailable for backhaul; 24,000 Dths
· AGT/TGP Lincoln Ma Tie Over Worches Receipt Meter (Pin 420350) - through approx 57% of IT increases receipts due to displacement gas unavailable for backhaul; 5,269 Dths
SEGMENT RESTRICTIONS
· STA 1 (Segment 101 BH) - through 100% of SOP increases due to operational concerns; 81,718 Dths
· MLV 509 Muskrat Line (Segment 515 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 4,494 Dths
· STA 523 West (Segment 516 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 14,964 Dths
· STA 860 South 500 Line (Segment 548 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 10,000 Dths
· STA 114 East (Segment 114 BH) - through SIPps increases due to force majeure
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 368,652 Dths
· MLV 314 East (Segment 314 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 214,526 Dths
· STA 315 (Segment 315 BH) - through approx 79% of SOP increases due to nominations in excess of operational capacity; 225,162 Dths
· STA 317 (Segment 317 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 74,596 Dths
· STA 321 (Segment 321 FH) - through approx 50% of SOP increases due to nominations in excess of operational capacity; 63,075 Dths
· MLV 330 (Segment 324 FH) - through approx 46% of SOP increases due to nominations in excess of operational capacity; 19,844 Dths
· Z5hc North (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 126,389 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 154,499 Dths
· STA 249 (Segment 249 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 51,439 Dths
· STA 261 Discharge East (Segment 261 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 30,766 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 175,443 Dths
LINEPACK RESTRICTIONS
PAYBACK NOMINATIONS WILL BE EVALUATED AT EACH CYCLE AND SCHEDULED ONLY IF OPERATIONALLY FEASIBLE.
STORAGE RESTRICTIONS
No Authorized Overrun Injections Services under Rate Schedule FS-AO at the following storage fields:
o Northern MA (460018) storage field
o Portland MA (460025) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service in Zones 4, 5 and 6
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service in Zones 4, 5 and 6
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.