Effective Timely Cycle (9:00) for the gas day of Sunday, August 30, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 ON THE 500 lINE FROM STA 527 TO STA 542 FOR OVERTAKES from the system OR UNDERDELIVERieS into the system FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST AND NORTH OF STA 219 FOR UNDERTAKES FROM THE SYSTEM OR OVERDELIVERIES INTO THE SYSTEM FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
METER RESTRICTIONS
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through 100% of SIPss due to operational concerns; 5,000 Dths
· FGT/TGP Carnes Mississippi Stone Delivery Meter (Pin 420366) - through 100% of PIP due to planned and unplanned maintenance;
· ATMOS-TX/TGP Katy Exch Waller Receipt Meter (Pin 412100) - through approx 7% of SA due to nominations in excess of operational capacity; 6,516 Dths
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through 100% of SOP due to operational concerns; 20,000 Dths
· GULFSTH/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through 100% of SIPss due to operational concerns; 139 Dths
· TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10,000 Dths
SEGMENT RESTRICTIONS
· STA 534 South Of Pool (Segment 530 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 450 Dths
· STA 1 (Segment 101 BH) - through 100% of SOP due to operational concerns; 91,243 Dths
· MLV 509 Muskrat Line (Segment 515 BH) - through 100% of SOP due to nominations in excess of operational capacity; 4,494 Dths
· STA 523 West (Segment 516 FH) - through 100% of SOP due to nominations in excess of operational capacity; 34,952 Dths
· STA 114 East (Segment 114 BH) - into PIP due to force majeure
· STA 204 (Segment 204 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 155 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to nominations in excess of operational capacity; 378,652 Dths
· MLV 314 East (Segment 314 BH) - through approx 87% of SOP due to nominations in excess of operational capacity; 344,626 Dths
· STA 315 (Segment 315 BH) - through approx 82% of SOP due to nominations in excess of operational capacity; 425,077 Dths
· STA 317 (Segment 317 BH) - through approx 84% of SOP due to nominations in excess of operational capacity; 167,943 Dths
· STA 321 (Segment 321 FH) - through approx 46% of SOP due to nominations in excess of operational capacity; 505,132 Dths
· STA 325 (Segment 324 FH) - through approx 12% of SOP due to nominations in excess of operational capacity; 60,258 Dths
· MLV 330 (Segment 324 FH) - through approx 29% of SOP due to nominations in excess of operational capacity; 178,247 Dths
· Z5hc North (Segment 299 FH) - through approx 80% of SOP due to nominations in excess of operational capacity; 544,689 Dths
· STA 245 (Segment 245 FH) - through approx 75% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 550,852 Dths
· STA 249 (Segment 249 FH) - through approx 54% of SOP due to nominations in excess of operational capacity; 299,124 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 25% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 40,611 Dths
· MLV 273 (Segment 284 FH) - through approx 97% of SOP due to nominations in excess of operational capacity; 259,378 Dths
LINEPACK RESTRICTIONS
PAYBACK NOMINATIONS WILL BE EVALUATED AT EACH CYCLE AND SCHEDULED ONLY IF OPERATIONALLY FEASIBLE.
STORAGE RESTRICTIONS
No Authorized Overrun Injections Services under Rate Schedule FS-AO at the following storage fields:
o Northern MA (460018) storage field
o Portland MA (460025) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service in Zones 4, 5 and 6
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service in Zones 4, 5 and 6
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.