Effective Timely Cycle (9:00) for the gas day of Wednesday, August 05, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 ON THE 500 lINE FROM STA 527 TO STA 542 FOR OVERTAKES OR UNDERDELIVIERS FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
METER RESTRICTIONS
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through 100% of SIPss due to pipeline maintenance at delivery location; 5,000 Dths
· FGT/TGP Carnes Mississippi Stone Delivery Meter (Pin 420366) - through 100% of PIP due to planned and unplanned maintenance
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through 100% of SOP due to operational concerns; 20,000 Dths
· GULFSTH/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through 100% of SIPss due to pipeline maintenance at delivery location; 1,135 Dths
· LEAF/TGP Jasper County: Rip 538 2 5 Delivery Meter (Pin 412789) - through 100% of SOP due to pipeline maintenance at delivery location; 9,995 Dths
· AHMLFG/TGP Rumpke Biogas Buyback De Delivery Meter (Pin 55964) - through approx 8% of IT due to nominations in excess of operational capacity; 265 Dths
SEGMENT RESTRICTIONS
· STA 542 (Segment 539 BH) - through SIPsp due to force majeure
· STA 534 South Of Pool (Segment 530 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 450 Dths
· STA 1 (Segment 101 BH) - through 100% of SOP due to operational concerns; 90,510 Dths
· MLV 509 Muskrat Line (Segment 515 BH) - through 100% of SOP due to nominations in excess of operational capacity; 2,994 Dths
· STA 823 Muskrat Line (Segment 509 BH) - through 100% of SOP due to nominations in excess of operational capacity; 1,995 Dths
· STA 523 West (Segment 516 FH) - through 100% of SOP due to nominations in excess of operational capacity; 37,494 Dths
· MLV 548 (Segment 542 BH) - through 100% of SOP due to operational concerns; 5,000 Dths
· STA 110 South (Segment 187 BH) - through SIPsp due to operational concerns
· STA 204 (Segment 204 BH) - through 100% of SOP due to operational concerns; 75 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 368,652 Dths
· MLV 314 East (Segment 314 BH) - through approx 85% of SOP due to nominations in excess of operational capacity; 448,407 Dths
· STA 315 (Segment 315 BH) - through approx 82% of SOP due to nominations in excess of operational capacity; 539,005 Dths
· STA 317 (Segment 317 BH) - through approx 61% of SOP due to nominations in excess of operational capacity; 95,784 Dths
· STA 321 (Segment 321 FH) - through approx 47% of SOP due to nominations in excess of operational capacity; 536,375 Dths
· STA 325 (Segment 324 FH) - through approx 15% of SOP due to nominations in excess of operational capacity; 86,142 Dths
· MLV 330 (Segment 324 FH) - through approx 34% of SOP due to nominations in excess of operational capacity; 214,371 Dths
· MLV 355 (Segment 355 BH) - through 100% of IT due to operational concerns; 12,470 Dths
· Z5hc North (Segment 299 FH) - through approx 84% of SOP due to nominations in excess of operational capacity; 611,874 Dths
· STA 245 (Segment 245 FH) - through approx 90% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 781,166 Dths
· STA 249 (Segment 249 FH) - through approx 70% of SOP due to nominations in excess of operational capacity; 374,276 Dths
· STA 261 Discharge East (Segment 261 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 161,109 Dths
· MLV 273 (Segment 284 FH) - through approx 94% of SOP due to nominations in excess of operational capacity; 241,281 Dths
LINEPACK RESTRICTIONS
Payback nominations will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
NONE
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.