Effective Intraday 2 Cycle (18:00) for the gas day of Tuesday, June 30, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR 500 LINE (INCLUDES SEGMENTS 527, 529, 530, 534, 539, 542, 548, 860) FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES ONLY
SEGMENT RESTRICTIONS
· STA 534 South Of Pool (Segment 530 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 425 Dths
· STA 1 (Segment 101 BH) - through 100% of SOP increases due to operational concerns; 39,938 Dths
· STA 823 Muskrat Line (Segment 509 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 2,500 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 358,652 Dths
· MLV 314 East (Segment 314 BH) - through approx 96% of SOP increases due to nominations in excess of operational capacity; 182,581 Dths
· STA 315 (Segment 315 BH) - through approx 72% of SOP increases due to nominations in excess of operational capacity; 164,896 Dths
· STA 317 (Segment 317 BH) - through approx 92% of SOP increases due to nominations in excess of operational capacity; 74,761 Dths
· STA 321 (Segment 321 FH) - through approx 47% of SOP increases due to nominations in excess of operational capacity; 36,212 Dths
· MLV 330 (Segment 324 FH) - through approx 61% of SOP increases due to nominations in excess of operational capacity; 43,198 Dths
· Z5 HC North (Segment 299 FH) - through approx 97% of SOP increases due to nominations in excess of operational capacity; 198,258 Dths
· STA 245 (Segment 245 FH) - through approx 97% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 237,823 Dths
· STA 249 (Segment 249 FH) - through approx 94% of SOP increases due to nominations in excess of operational capacity; 132,729 Dths
· STA 261 Discharge East (Segment 261 FH) - through SIPps increases due to scheduled maintenance and nominations in excess of operational capacity
· MLV 273 (Segment 284 FH) - through approx 95% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 53,425 Dths
LINEPACK RESTRICTIONS
Payback nominations will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
NONE
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.