Effective Timely Cycle (9:00) for the gas day of Wednesday, February 25, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 for all areas east of Sta 245 on the 200 Line and east of sta 321 on the 300 Line for over-takes from the system or under-deliveries into the system for all Balancing Parties
METER RESTRICTIONS
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through 100% of IT due to operational concerns; 20,000 Dths
· HICKORYR/TGP Mohawk Road Power Plt Delivery Meter (Pin 50789) - through approx 12% of PAYBACK TGP due to nominations in excess of operational capacity; 3,570 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 98% of SIPss due to nominations in excess of operational capacity; 78,214 Dths
· Wright Receipt Meter (Pin 412181) - through approx 76% of SIPss due to nominations in excess of operational capacity; 363,527 Dths
SEGMENT RESTRICTIONS
· STA 25 (Segment 125 FH) - through approx 54% of SOP due to nominations in excess of operational capacity; 324,680 Dths
· STA 47 (Segment 143 FH) - through 100% of SOP due to nominations in excess of operational capacity; 82,990 Dths
· STA 63 (Segment 163 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 125,017 Dths
· STA 823 Muskrat Line (Segment 509 BH) - through approx 34% of SOP due to nominations in excess of operational capacity; 15,747 Dths
· STA 523 West (Segment 516 FH) - through approx 22% of SOP due to nominations in excess of operational capacity; 9,263 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to nominations in excess of operational capacity; 341,142 Dths
· MLV 314 East (Segment 314 BH) - through approx 88% of SOP due to nominations in excess of operational capacity; 455,483 Dths
· STA 315 (Segment 315 BH) - through approx 76% of SOP due to nominations in excess of operational capacity; 472,159 Dths
· STA 317 (Segment 317 BH) - through approx 32% of SOP due to nominations in excess of operational capacity; 49,679 Dths
· STA 321 (Segment 321 FH) - through approx 87% of SOP due to nominations in excess of operational capacity; 1,132,554 Dths
· STA 325 (Segment 324 FH) - through approx 55% of SOP due to nominations in excess of operational capacity; 247,322 Dths
· MLV 330 (Segment 324 FH) - through approx 49% of SOP due to nominations in excess of operational capacity; 168,569 Dths
· MLV 336 East (Segment 336 FH) - through 100% of SOP due to nominations in excess of operational capacity; 40,631 Dths
· MLV 355 (Segment 355 BH) - through 100% of SOP due to operational concerns; 12,109 Dths
· STA 219 North (Segment 219 FH) - through 100% of SOP due to nominations in excess of operational capacity; 11,000 Dths
· STA 224 (Segment 224 FH) - through 100% of SOP due to nominations in excess of operational capacity; 159,025 Dths
· Z5hc North (Segment 299 FH) - through approx 96% of SOP due to nominations in excess of operational capacity; 718,172 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP due to nominations in excess of operational capacity; 621,867 Dths
· STA 249 (Segment 249 FH) - through 100% of SOP due to nominations in excess of operational capacity; 425,407 Dths
· STA 254 (Segment 249 FH) - through approx 94% of SOP due to nominations in excess of operational capacity; 210,897 Dths
· STA 261 Discharge East (Segment 261 FH) - through 100% of SOP due to nominations in excess of operational capacity; 182,024 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP due to nominations in excess of operational capacity; 52,322 Dths
LINEPACK RESTRICTIONS
Payback nominations will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
· No Authorized Overrun Withdrawal Services under Rate Schedule FS-AO at the following storage fields:
o Northern MA (460018)
o Portland MA (460025)
o Portland PA (460020)
o Bear Creek PA (460017)
· Customers who elected swing on storage or storage swing options for balancing (SOS or SSO) may only swing up to their Maximum Daily Withdrawal (MDWQ) until further notice
· No Authorized Overrun Withdrawal Services under Rate Schedule FS-F at the following storage field:
o Pine Prairie Virtual (54628)
· No Interruptible Storage Withdrawal Services under Rate Schedule IS at the following storage fields:
o Northern MA (460018) IS-MA
o Bear Creek PA (460017) IS-PA
· No Loans or Park Withdrawals under Rate Schedule PAL utilizing the PAL-D or PAL-AO services system-wide
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.