Effective Intraday 1 Cycle (14:00) for the gas day of Friday, December 12, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 245 ON THE 200 LINE AND EAST OF STA 321 ON THE 300 LINE FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through approx 15% of SIPss increases due to nominations in excess of operational capacity; 2,668 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - into PIP increases due to nominations in excess of operational capacity
· Wright Receipt Meter (Pin 412181) - through approx 98% of SOP increases due to nominations in excess of operational capacity; 114,836 Dths
SEGMENT RESTRICTIONS
· STA 47 (Segment 143 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 61,524 Dths
· STA 860 (Segment 860 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 523 West (Segment 516 FH) - through approx 93% of SOP increases due to nominations in excess of operational capacity; 23,547 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 343,132 Dths
· MLV 314 East (Segment 314 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 220,509 Dths
· STA 315 (Segment 315 BH) - through approx 72% of SOP increases due to nominations in excess of operational capacity; 155,800 Dths
· STA 317 (Segment 317 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 63,000 Dths
· STA 321 (Segment 321 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 397,138 Dths
· MLV 330 (Segment 324 FH) - through approx 98% of SOP increases due to nominations in excess of operational capacity; 127,548 Dths
· STA 224 (Segment 224 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 135,200 Dths
· Z5hc North (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 355,570 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 453,612 Dths
· STA 254 (Segment 249 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 155,100 Dths
· STA 261 Discharge East (Segment 261 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 108,850 Dths
LINEPACK RESTRICTIONS
Payback nominations will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
NONE
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.