Effective Timely Cycle (9:00) for the gas day of Saturday, October 25, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 SYSTEM WIDE (EXCLUDING AREAS SOUTH OF STA 1 AND THE 500 LINE SEGMENTS 524, 527, 529, 530, 534, 539, 542, 548, 860) FOR UNDER-TAKES OR OVER-DELIVERIES FOR ALL BALANCING PARTIES
OFO DAILY CRITICAL DAY 1 FOR THE 500 LINE ONLY (SEGMENTS 527, 529, 530, 534, 539) FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through 100% of SOP due to operational concerns; 10,500 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 79% of SIPss due to nominations in excess of operational capacity; 101,554 Dths
· EGTS/TGP Ellisburg Injection Potter Receipt Meter (Pin 460012) - through 100% of IT due to storage capacity constraint; 15,136 Dths
· EGTS/TGP Harrison Injection Potter Receipt Meter (Pin 460004) - through 100% of IT due to storage capacity constraint; 15,000 Dths
SEGMENT RESTRICTIONS
· STA 542 (Segment 539 BH) - into PIP due to scheduled maintenance and nominations in excess of operational capacity
· STA 823 Muskrat Line (Segment 509 BH) - through 100% of SOP due to operational concerns; 10,000 Dths
· STA 823 (Segment 823 BH) - through 100% of SOP due to nominations in excess of operational capacity; 1,800 Dths
· STA 523 West (Segment 516 FH) - through 100% of SOP due to nominations in excess of operational capacity; 10,969 Dths
· STA 219 South (Segment 217 BH) - through 100% of SOP due to operational concerns; 5,040 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to nominations in excess of operational capacity; 593,941 Dths
· MLV 314 East (Segment 314 BH) - through approx 87% of SOP due to nominations in excess of operational capacity; 503,068 Dths
· STA 315 (Segment 315 BH) - through approx 78% of SOP due to nominations in excess of operational capacity; 576,576 Dths
· STA 317 (Segment 317 BH) - through approx 42% of SOP due to nominations in excess of operational capacity; 81,527 Dths
· STA 321 (Segment 321 FH) - through approx 49% of SOP due to nominations in excess of operational capacity; 541,993 Dths
· MLV 330 (Segment 324 FH) - through approx 24% of SOP due to nominations in excess of operational capacity; 117,667 Dths
· MLV 336 East (Segment 336 FH) - through approx 58% of SOP due to nominations in excess of operational capacity; 32,701 Dths
· STA 313Hcg - Z4 Hc (Segment 399 FH) - through 100% of IT due to nominations in excess of operational capacity; 119,300 Dths
· Z5hc North (Segment 299 FH) - through approx 87% of SOP due to nominations in excess of operational capacity; 756,827 Dths
· STA 245 (Segment 245 FH) - through approx 88% of SOP due to nominations in excess of operational capacity; 843,498 Dths
· STA 249 (Segment 249 FH) - through approx 91% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 566,970 Dths
· MLV 256 East (Segment 256 FH) - through approx 26% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 47,315 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 22% of SOP due to nominations in excess of operational capacity; 35,281 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP due to nominations in excess of operational capacity; 58,812 Dths
LINEPACK RESTRICTIONS
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service
· Paybacks will be evaluated at each cycle and scheduled only if operationally feasible
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.