Effective Intraday 1 Cycle (14:00) for the gas day of Wednesday, September 10, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
NONE
METER RESTRICTIONS
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 16% of SIPps increases due to nominations in excess of operational capacity; 109,998 Dths
· AGT/TGP Mendon Mass Tie Over Worche Delivery Meter (Pin 420285) - through approx 53% of SOP receipt increases due to displacement gas unavailable for backhaul; 8,866 Dths
SEGMENT RESTRICTIONS
· STA 9 (Segment 109 BH) - through SIPsp increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 40 South Of Carthage (Segment 132 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 12,281 Dths
· STA 823 (Segment 823 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 16,888 Dths
· STA 860 (Segment 860 BH) - through SIPss increases due to scheduled maintenance and nominations in excess of operational capacity
· MLV 548 (Segment 542 BH) - through SIPss increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 110 South (Segment 187 BH) - through SIPss increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 204 (Segment 204 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 307 (Segment 307 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· MLV 314 East (Segment 314 BH) - through approx 98% of SOP increases due to nominations in excess of operational capacity; 231,667 Dths
· STA 315 (Segment 315 BH) - through approx 61% of SOP increases due to nominations in excess of operational capacity; 160,485 Dths
· STA 317 (Segment 317 BH) - through approx 94% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 102,687 Dths
· STA 321 (Segment 321 FH) - through approx 76% of SOP increases due to nominations in excess of operational capacity; 163,938 Dths
· MLV 330 (Segment 324 FH) - through approx 67% of SOP increases due to nominations in excess of operational capacity; 76,867 Dths
· Z5hc North (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 307,537 Dths
· STA 245 (Segment 245 FH) - through approx 98% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 472,648 Dths
LINEPACK RESTRICTIONS
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service
· Paybacks will be evaluated at each cycle and scheduled only if operationally feasible
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.