Effective Evening Cycle (9:00) for the gas day of Tuesday, September 09, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
NONE
METER RESTRICTIONS
· WHISTLEP/TGP Whistle Receipt Nueces Receipt Meter (Pin 54847) - through approx 81% of SIPss increases due to nominations in excess of operational capacity; 29,803 Dths
· ANR/TGP TGP Anr Greenville Intercon Delivery Meter (Pin 420941) - through 100% of SOP increases due to operational concerns; 23 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through 100% of SOP increases due to operational concerns; 20,000 Dths
· TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SOP receipt increases due to displacement gas unavailable for backhaul; 1,915 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 97% of SIPss increases due to nominations in excess of operational capacity; 94,543 Dths
SEGMENT RESTRICTIONS
· STA 9 (Segment 109 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 80,085 Dths
· STA 40 South Of Carthage (Segment 132 FH) - through approx 91% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 17,277 Dths
· STA 823 (Segment 823 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 17,246 Dths
· STA 860 (Segment 860 BH) - through SIPsp increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 110 South (Segment 187 BH) - through SIPsp increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 204 (Segment 204 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 219 South (Segment 217 BH) - through 100% of SOP increases due to operational concerns; 20,000 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 418,714 Dths
· MLV 314 East (Segment 314 BH) - through approx 86% of SOP increases due to nominations in excess of operational capacity; 258,855 Dths
· STA 317 (Segment 317 BH) - through approx 88% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 293,471 Dths
· STA 321 (Segment 321 FH) - through approx 59% of SOP increases due to nominations in excess of operational capacity; 191,885 Dths
· MLV 330 (Segment 324 FH) - through approx 59% of SOP increases due to nominations in excess of operational capacity; 80,702 Dths
· STA 224 (Segment 224 FH) - through approx 36% of SOP increases due to nominations in excess of operational capacity; 7,491 Dths
· Z5hc North (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 302,881 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 466,950 Dths
LINEPACK RESTRICTIONS
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service
· Paybacks will be evaluated at each cycle and scheduled only if operationally feasible
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.