Effective Timely Cycle (9:00) for the gas day of Saturday, June 28, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR THE 500 LINE ONLY (SEGMENTS 527,529, 530, 534, 539, 542, 548, 860) FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· GULFSTH/TGP Kiln Miss Exchange Hanc Receipt Meter (Pin 420383) - through approx 100 % of SIPss due to operational concerns; 20,269 Dths
· KMTEJAS/TGP Jackson (Ganado) Delivery Meter (Pin 49803) - through approx 4 % of SOP due to operational concerns; 65,845 Dths
· TGP/SNG Bear Creek Injection Delivery Meter (Pin 405367) - through approx 100 % of SOP due to operational concerns; 5,000 Dths
· GULFSTH/TGP Heidelberg Gum Ave: Rip Delivery Meter (Pin 412754) - through approx 100 % of SOP deliveries due to displacement gas unavailable for backhaul; 9,984 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 60 % of SIPss due to nominations in excess of operational capacity; 54,428 Dths
SEGMENT RESTRICTIONS
· STA 17 (Segment 117 FH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 12,703 Dths
· STA 823 (Segment 823 BH) - through approx 95 % of SOP due to nominations in excess of operational capacity; 30,795 Dths
· STA 834 (Segment 834 BH) - through approx 100 % of SA due to scheduled maintenance and nominations in excess of operational capacity; 17,900 Dths
· STA 523 West (Segment 516 FH) - through approx 100 % of SOP due to nominations in excess of operational capacity; 39,888 Dths
· STA 860 South 500 Line (Segment 548 BH) - into PIP due to scheduled maintenance and nominations in excess of operational capacity
· STA 204 (Segment 204 BH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 13,360 Dths
· STA 307 (Segment 307 BH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 408,714 Dths
· MLV 314 East (Segment 314 BH) - through approx 94 % of SOP due to nominations in excess of operational capacity; 650,634 Dths
· STA 315 (Segment 315 BH) - through approx 83 % of SOP due to nominations in excess of operational capacity; 647,606 Dths
· STA 317 (Segment 317 BH) - through approx 42 % of SOP due to nominations in excess of operational capacity; 59,099 Dths
· STA 321 (Segment 321 FH) - through approx 53 % of SOP due to nominations in excess of operational capacity; 560,099 Dths
· STA 325 (Segment 324 FH) - through approx 86 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 318,536 Dths
· Z5hc North (Segment 299 FH) - through approx 81 % of SOP due to nominations in excess of operational capacity; 754,389 Dths
· STA 245 (Segment 245 FH) - through approx 76 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 709,122 Dths
· STA 249 (Segment 249 FH) - through approx 49 % of SOP due to nominations in excess of operational capacity; 322,569 Dths
· MLV 273 (Segment 284 FH) - through approx 99 % of SOP due to nominations in excess of operational capacity; 460,677 Dths
LINEPACK RESTRICTIONS
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service
· Paybacks will be evaluated at each cycle and scheduled only if operationally feasible
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.