Effective Timely Cycle (9:00) for the gas day of Monday, June 02, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 4, 5 AND 6 FOR OVER-DELIVERIES INTO THE SYSTEM OR UNDER-TAKES OUT OF THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· GULFSTH/TGP Kiln Miss Exchange Hanc Delivery Meter (Pin 420383) - through approx 100 % of SOP due to imbalance management quantity exceeded; 100 Dths
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through approx 100 % of SOP due to operational concerns; 5,000 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 100 % of SOP due to operational concerns; 5,000 Dths
· NRGBM/TGP Beirne Hill Sales Bradfor Delivery Meter (Pin 48061) - through approx 42 % of IT (through a rate of .1775) due to nominations in excess of operational capacity; 23,432 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 53 % of SIPss due to nominations in excess of operational capacity; 78,596 Dths
SEGMENT RESTRICTIONS
· STA 114 East (Segment 114 BH) - into PIP due to scheduled maintenance and nominations in excess of operational capacity
· STA 307 (Segment 307 BH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 408,714 Dths
· MLV 314 East (Segment 314 BH) - through approx 95 % of SOP due to nominations in excess of operational capacity; 654,056 Dths
· STA 315 (Segment 315 BH) - through approx 90 % of SOP due to nominations in excess of operational capacity; 741,919 Dths
· STA 321 (Segment 321 FH) - through approx 47 % of SOP due to nominations in excess of operational capacity; 466,081 Dths
· MLV 330 (Segment 324 FH) - through approx 33 % of SOP due to nominations in excess of operational capacity; 157,043 Dths
· Z5hc North (Segment 299 FH) - through approx 83 % of SOP due to nominations in excess of operational capacity; 738,467 Dths
· STA 245 (Segment 245 FH) - through approx 86 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 840,092 Dths
· STA 249 (Segment 249 FH) - through approx 62 % of SOP due to nominations in excess of operational capacity; 397,411 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 7 % of SOP due to nominations in excess of operational capacity; 12,480 Dths
· MLV 273 (Segment 284 FH) - through approx 93 % of SOP due to nominations in excess of operational capacity; 433,136 Dths
LINEPACK RESTRICTIONS
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service
· Paybacks will be evaluated at each cycle and scheduled only if operationally feasible
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.