Effective Timely Cycle (9:00) for the gas day of Sunday, June 01, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 4, 5 AND 6 FOR OVER-DELIVERIES INTO THE SYSTEM OR UNDER-TAKES OUT OF THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· GULFSTH/TGP Kiln Miss Exchange Hanc Delivery Meter (Pin 420383) - through 100% of SOP due to imbalance management quantity exceeded; 100 Dths
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through 100% of SOP due to operational concerns; 5,000 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through 100% of SOP due to operational concerns; 5,000 Dths
· NRGBM/TGP Beirne Hill Sales Bradfor Delivery Meter (Pin 48061) - through approx 43% of IT due to nominations in excess of operational capacity; 23,964 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 53% of SIPss due to nominations in excess of operational capacity; 78,578 Dths
SEGMENT RESTRICTIONS
· STA 860 (Segment 860 BH) - through 100% of IT due to force majeure at STA 860; 100 Dths
· STA 114 East (Segment 114 BH) - into PIP due to scheduled maintenance and nominations in excess of operational capacity
· STA 307 (Segment 307 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 423,714 Dths
· MLV 314 East (Segment 314 BH) - through approx 92% of SOP due to nominations in excess of operational capacity; 639,481 Dths
· STA 315 (Segment 315 BH) - through approx 88% of SOP due to nominations in excess of operational capacity; 726,888 Dths
· STA 321 (Segment 321 FH) - through approx 51% of SOP due to nominations in excess of operational capacity; 508,658 Dths
· MLV 330 (Segment 324 FH) - through approx 40% of SOP due to nominations in excess of operational capacity; 189,516 Dths
· Z5hc North (Segment 299 FH) - through approx 81% of SOP due to nominations in excess of operational capacity; 718,132 Dths
· STA 245 (Segment 245 FH) - through approx 86% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 837,714 Dths
· STA 249 (Segment 249 FH) - through approx 61% of SOP due to nominations in excess of operational capacity; 395,685 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 7% of SOP due to nominations in excess of operational capacity; 11,910 Dths
· MLV 273 (Segment 284 FH) - through approx 93% of SOP due to nominations in excess of operational capacity; 432,907 Dths
LINEPACK RESTRICTIONS
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD service
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PAL-AO service
· Paybacks will be evaluated at each cycle and scheduled only if operationally feasible
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO as well as No Authorized Overrun Injections in excess of Maximum Daily Injection Quantity (MDIQ) but below Maximum Daily Withdrawal Quantity (MDWQ) at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.