Effective Timely Cycle (9:00) for the gas day of Saturday, April 19, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 SYSTEMWIDE (EXCLUDING ALL AREAS SOUTH OF STA 1) FOR UNDER-TAKES FROM THE SYSTEM OR OVER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· KMTEJAS/TGP Zim Dehydration Starr Receipt Meter (Pin 410729) - through approx 19 % of SA due to nominations in excess of operational capacity; 14,300 Dths
· Tres PAL/TGP Tres Palacios Storage: Delivery Meter (Pin 421055) - through approx 100 % of SIPss due to operational concerns; 70,000 Dths
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through approx 100 % of SOP due to operational concerns; 4,375 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 100 % of SOP due to operational concerns; 5,000 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 33 % of SIPss due to nominations in excess of operational capacity; 35,758 Dths
SEGMENT RESTRICTIONS
· STA 25 (Segment 125 FH) - through approx 30 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 45,099 Dths
· STA 823 (Segment 823 BH) - through approx 36 % of SOP due to nominations in excess of operational capacity; 11,689 Dths
· MLV 548 (Segment 542 BH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 30,000 Dths
· STA 307 (Segment 307 BH) - through approx 92 % of SOP due to nominations in excess of operational capacity; 376,099 Dths
· MLV 314 East (Segment 314 BH) - through approx 94 % of SOP due to nominations in excess of operational capacity; 503,221 Dths
· STA 315 (Segment 315 BH) - through approx 87 % of SOP due to nominations in excess of operational capacity; 616,682 Dths
· STA 321 (Segment 321 FH) - through approx 51 % of SOP due to emergent repair at STA 321 UNIT 5B; 501,141 Dths
· MLV 330 (Segment 324 FH) - through approx 18 % of SOP due to nominations in excess of operational capacity; 88,120 Dths
· Z5hc North (Segment 299 FH) - through approx 72 % of SOP due to nominations in excess of operational capacity; 639,081 Dths
· STA 245 (Segment 245 FH) - through approx 67 % of SOP due to nominations in excess of operational capacity; 701,846 Dths
· STA 249 (Segment 249 FH) - through approx 44 % of SOP due to nominations in excess of operational capacity; 326,188 Dths
· MLV 273 (Segment 284 FH) - through approx 83 % of SOP due to nominations in excess of operational capacity; 232,272 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
NONE
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.