Effective Evening Cycle (9:00) for the gas day of Monday, April 14, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
NONE
METER RESTRICTIONS
· Tres PAL/TGP Tres Palacios Storage: Delivery Meter (Pin 421055) - through 100% of SIPss increases due to imbalance management quantity exceeded; 70,000 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through 100% of SOP increases due to operational concerns; 5,000 Dths
· TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 56% of SIPss increases due to nominations in excess of operational capacity; 17,803 Dths
SEGMENT RESTRICTIONS
· STA 25 (Segment 125 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 134,124 Dths
· STA 40 South Of Carthage (Segment 132 FH) - through 100% of SOP increases due to maintenance and emergent repair at STA 40 Unit 1 C; 59,092 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 330,064 Dths
· MLV 314 East (Segment 314 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 283,727 Dths
· STA 315 (Segment 315 BH) - through approx 90% of SOP increases due to nominations in excess of operational capacity; 375,752 Dths
· STA 321 (Segment 321 FH) - through approx 97% of SOP increases due to emergent repair at STA 321 UNIT 5B; 593,033 Dths
· MLV 330 (Segment 324 FH) - through approx 42% of SOP increases due to nominations in excess of operational capacity; 54,801 Dths
· Z5hc North (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 389,848 Dths
· STA 245 (Segment 245 FH) - through approx 95% of SOP increases due to nominations in excess of operational capacity; 402,301 Dths
· STA 249 (Segment 249 FH) - through approx 88% of SOP increases due to nominations in excess of operational capacity; 239,636 Dths
· STA 261 Discharge East (Segment 261 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 50,288 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 202,661 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.