Effective Evening Cycle (9:00) for the gas day of Friday, April 04, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
NONE
METER RESTRICTIONS
· LASERGTH/TGP Riverside Wilson 1 Nu Receipt Meter (Pin 412124) - through approx 19 % of SA increases due to nominations in excess of operational capacity; 1,917 Dths
· TRNSCO/TGP Kinder La Exch (Bi 1 Delivery Meter (Pin 420373) - through approx 100 % of SOP increases due to operational concerns; 14,980 Dths
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through approx 100 % of SOP increases due to operational concerns; 4,953 Dths
· GULFSTH/TGP Worthy Road South Ouach Delivery Meter (Pin 49780) - through approx 100 % of SIPps increases due to operational concerns; 18,821 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 100 % of SOP increases due to operational concerns; 11,149 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 100 % of SIPss increases due to nominations in excess of operational capacity; 30,903 Dths
SEGMENT RESTRICTIONS
· STA 823 Muskrat Line (Segment 509 BH) - through approx 100 % of SOP increases due to nominations in excess of operational capacity; 11,749 Dths
· STA 860 (Segment 860 BH) - through approx 100 % of PIP increases due to force majeure at STA 860; 73,926 Dths
· STA 307 (Segment 307 BH) - through approx 100 % of SOP increases due to nominations in excess of operational capacity; 433,714 Dths
· MLV 314 East (Segment 314 BH) - through approx 100 % of SOP increases due to nominations in excess of operational capacity; 295,825 Dths
· STA 315 (Segment 315 BH) - through approx 99 % of SOP increases due to nominations in excess of operational capacity; 433,381 Dths
· STA 321 (Segment 321 FH) - through approx 63 % of SOP increases due to emergent repair at STA 321 UNIT 5B; 151,779 Dths
· Z5hc North (Segment 299 FH) - through approx 100 % of SOP increases due to nominations in excess of operational capacity; 329,448 Dths
· STA 245 (Segment 245 FH) - through approx 94 % of SOP increases due to nominations in excess of operational capacity; 417,502 Dths
· STA 249 (Segment 249 FH) - through approx 89 % of SOP increases due to nominations in excess of operational capacity; 230,437 Dths
· MLV 273 (Segment 284 FH) - through approx 100 % of SOP increases due to nominations in excess of operational capacity; 222,389 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.