Effective Timely Cycle (9:00) for the gas day of Tuesday, April 01, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
NONE
METER RESTRICTIONS
· Tres PAL/TGP Tres Palacios Storage: Delivery Meter (Pin 421055) - through approx 100 % of SIPss due to imbalance management quantity exceeded; 38,339 Dths
· TRNSCO/TGP Kinder La Exch (Bi 1 Delivery Meter (Pin 420373) - through approx 100 % of SOP due to operational concerns; 4,986 Dths
· EGT/TGP Guthrie Exchange Ouachita Delivery Meter (Pin 412352) - through approx 100 % of SOP due to operational concerns; 3,398 Dths
· ANR/TGP TGP Anr Greenville Intercon Delivery Meter (Pin 420941) - through approx 100 % of IT due to operational concerns; 6,578 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 100 % of SIPps due to operational concerns; 6,402 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 80 % of SIPss due to nominations in excess of operational capacity; 107,936 Dths
SEGMENT RESTRICTIONS
· STA 834 (Segment 834 BH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 36,979 Dths
· STA 860 (Segment 860 BH) - through approx 100 % of SOP due to force majeure at STA 860; 15,308 Dths
· MLV 548 (Segment 542 BH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 30,000 Dths
· STA 307 (Segment 307 BH) - through approx 85 % of SOP due to nominations in excess of operational capacity; 297,974 Dths
· MLV 314 East (Segment 314 BH) - through approx 67 % of SOP due to nominations in excess of operational capacity; 219,219 Dths
· STA 315 (Segment 315 BH) - through approx 62 % of SOP due to nominations in excess of operational capacity; 319,851 Dths
· STA 321 (Segment 321 FH) - through approx 87 % of SOP due to emergent repair at STA 321 UNIT 5B; 667,286 Dths
· MLV 330 (Segment 324 FH) - through approx 34 % of SOP due to nominations in excess of operational capacity; 124,259 Dths
· MLV 336 East (Segment 336 FH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 86,986 Dths
· MLV 355 (Segment 355Fh) - through approx 100 % of SOP due to operational concerns; 5,000 Dths
· STA 224 (Segment 224 FH) - through approx 36 % of SOP due to nominations in excess of operational capacity; 158,994 Dths
· Z5hc North (Segment 299 FH) - through approx 86 % of SOP due to nominations in excess of operational capacity; 694,430 Dths
· STA 237 East Of Z5w Pool (Segment 237 FH) - through approx 100 % of SOP due to scheduled maintenance and nominations in excess of operational capacity; 24,718 Dths
· STA 245 (Segment 245 FH) - through approx 94 % of SOP due to nominations in excess of operational capacity; 836,670 Dths
· STA 249 (Segment 249 FH) - through approx 73 % of SOP due to nominations in excess of operational capacity; 387,986 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 22 % of SOP due to nominations in excess of operational capacity; 39,429 Dths
· MLV 273 (Segment 284 FH) - through approx 95 % of SOP due to nominations in excess of operational capacity; 285,049 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.