Effective Intraday 1 Cycle (14:00) for the gas day of Wednesday, October 09, 2024 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ZONES L AND 1 ON THE 500 LINE ONLY FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 4, 5 AND 6 FOR UNDER-TAKES OUT OF THE SYSTEM OR OVER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· GULFSTH/TGP Worthy Road South Delivery Meter (Pin 49780) - through approx 100 % of SIPps increases due to operational concerns; 27,966 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 44 % of SIPss increases due to nominations in excess of operational capacity; 14,597 Dths
SEGMENT RESTRICTIONS
· STA 17 (Segment 117 BH) - through approx 100 % of IT increases due to scheduled maintenance and nominations in excess of operational capacity; 104,010 Dths
· STA 834 (Segment 834 BH) - through approx 61 % of SA increases due to nominations in excess of operational capacity; 15,043 Dths
· STA 87 South 800 Line (Segment 860 BH) - through approx 100 % of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 11,200 Dths
· STA 110 South (Segment 187 BH) - through approx 100 % of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 9,982 Dths
· STA 204 (Segment 204 BH) - through approx 100 % of SIPss increases due to scheduled maintenance and nominations in excess of operational capacity; 2,392 Dths
· STA 307 (Segment 307 BH) - through approx 100 % of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 254,182 Dths
· MLV 314 East (Segment 314 BH) - through approx 99 % of SOP increases due to nominations in excess of operational capacity; 423,303 Dths
· STA 321 (Segment 321 FH) - through approx 35 % of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 84,863 Dths
· STA 325 (Segment 324 FH) - through approx 21 % of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 19,647 Dths
· STA 224 (Segment 224 FH) - through approx 100 % of IT increases due to nominations in excess of operational capacity; 30,000 Dths
· Z5hc North (Segment 299 FH) - through approx 96 % of SOP increases due to nominations in excess of operational capacity; 190,906 Dths
· STA 245 (Segment 245 FH) - through approx 100 % of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 316,583 Dths
· STA 249 (Segment 249 FH) - through approx 76 % of SOP increases due to nominations in excess of operational capacity; 19,807 Dths
· MLV 273 (Segment 284 FH) - through approx 100 % of SOP increases due to nominations in excess of operational capacity; 104,126 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will not accept nominations for FSAO injections at all storage fields.
Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
Additionally, no Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.