Effective Timely Cycle (9:00) for the gas day of Thursday, August 22, 2024 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ZONES L AND 1 ON THE 500 LINE ONLY FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· TGP/SNG Bear Creek Injection Bienvi Delivery Meter (Pin 405367) - through 100% of SOP due to operational concerns; 10,099 Dths
· Pine PRA/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 21% of SIPss due to operational concerns; 10,260 Dths
· TRNSCO/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· HICKORYR/TGP Mohawk Road Power Plt Delivery Meter (Pin 50789) - through approx 13% of PAYBACK TGP due to nominations in excess of operational capacity; 3,143 Dths
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 5% of SIPps due to nominations in excess of operational capacity; 89,628 Dths
SEGMENT RESTRICTIONS
· STA 834 (Segment 834 BH) - through approx 25% of SA due to scheduled maintenance and nominations in excess of operational capacity; 21,132 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP due to force majeure at STA 860; 10,099 Dths
· MLV 548 (Segment 542 BH) - through 100% of IT due to scheduled maintenance and nominations in excess of operational capacity; 17,868 Dths
· STA 110 South (Segment 187 BH) - through 100% of SOP due to operational concerns; 9,891 Dths
· STA 204 (Segment 204 BH) - through approx 12% of PIP due to scheduled maintenance and nominations in excess of operational capacity; 199,879 Dths
· STA 219 South (Segment 217 BH) - through 100% of SOP due to operational concerns; 25,051 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 268,881 Dths
· MLV 314 East (Segment 314 BH) - through approx 92% of SOP due to nominations in excess of operational capacity; 282,343 Dths
· STA 315 (Segment 315 BH) - through approx 71% of SOP due to nominations in excess of operational capacity; 368,451 Dths
· STA 321 (Segment 321 FH) - through approx 40% of SOP due to nominations in excess of operational capacity; 386,959 Dths
· MLV 336 East (Segment 336 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 17,500 Dths
· Z5hc North (Segment 299 FH) - through approx 71% of SOP due to nominations in excess of operational capacity; 520,361 Dths
· STA 245 (Segment 245 FH) - through approx 72% of SOP due to nominations in excess of operational capacity; 627,879 Dths
· STA 249 (Segment 249 FH) - through approx 39% of SOP due to nominations in excess of operational capacity; 205,473 Dths
· MLV 273 (Segment 284 FH) - through approx 96% of SOP due to nominations in excess of operational capacity; 212,646 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will not accept nominations for FSAO injections at all storage fields.
Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
Additionally, no Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.