Effective Evening Cycle (9:00) for the gas day of Sunday, November 08, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 ON THE 500 lINE FROM STA 527 TO STA 542 FOR OVERTAKES from the system OR UNDERDELIVERieS into the SYSTEM FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST AND NORTH OF STA 219 FOR OVERDELIVERIES INTO THE SYSTEM OR UNDERTAKES OUT OF THE SYSTEM FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
METER RESTRICTIONS
· WHISTLEP/TGP Whistle Receipt Nueces Receipt Meter (Pin 54847) - through approx 79% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 15,580 Dths
· VCP/TGP Valley Crossing Allocation Receipt Meter (Pin 53608) - through approx 66% of SIPss increases due to scheduled maintenance and nominations in excess of operational capacity; 27,603 Dths
· NMP/TGP Gillrina Road Nueces Receipt Meter (Pin 47799) - through 100% of SA increases due to scheduled maintenance and nominations in excess of operational capacity; 30 Dths
· ENTRPRSE/TGP Agua Dulce Nueces Receipt Meter (Pin 411306) - through 100% of SA increases due to scheduled maintenance and nominations in excess of operational capacity; 1,032 Dths
· Pine Prairie /TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through 100% of SOP increases due to operational concerns; 10,000 Dths
· GULF SOUTH/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through 100% of SIPss increases due to operational concerns; 4,986 Dths
· Wright Delivery Meter (Pin 412181) - through 100% of SIPss increases deliveries due to displacement gas unavailable for backhaul; 5,000 Dths
SEGMENT RESTRICTIONS
· STA 409 - Donna Lateral (Segment 490 FH) - through approx 86% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 30,334 Dths
· MLV 406 (Segment 406 BH) - through approx 29% of SOP increases due to nominations in excess of operational capacity; 12,810 Dths
· STA 1 (Segment 101 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 454,735 Dths
· MLV 314 East (Segment 314 BH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 304,571 Dths
· STA 315 (Segment 315 BH) - through approx 84% of SOP increases due to nominations in excess of operational capacity; 272,419 Dths
· STA 317 (Segment 317 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 96,799 Dths
· STA 321 (Segment 321 FH) - through approx 55% of SOP increases due to nominations in excess of operational capacity; 167,186 Dths
· MLV 330 (Segment 324 FH) - through approx 58% of SOP increases due to nominations in excess of operational capacity; 104,372 Dths
· Z5 HC North (Segment 299 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 267,575 Dths
· STA 245 (Segment 245 FH) - through approx 72% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 199,004 Dths
· STA 249 (Segment 249 FH) - through approx 74% of SOP increases due to nominations in excess of operational capacity; 163,606 Dths
· MLV 273 (Segment 284 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 265,033 Dths
LINEPACK RESTRICTIONS
PAYBACK NOMINATIONS WILL BE EVALUATED AT EACH CYCLE AND SCHEDULED ONLY IF OPERATIONALLY FEASIBLE.
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD or PAL-AO services
Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under FS-PA storage service only with partner approvals.
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.