Effective Intraday 3 Cycle (22:00) for the gas day of Thursday, October 08, 2026 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 ON THE 500 lINE FROM STA 527 TO STA 542 FOR OVERTAKES from the system OR UNDERDELIVERieS into the system FOR ALL LMPA, SA ACTING AS BALANCING PARTIES AND LMMA BALANCING PARTIES
ofo daily critical day 1 for all areas east of sta 219 for overdeliveries into the system or undertakes out of the system for all lmpa, sa acting as balancing parties and lmma balancing parties
METER RESTRICTIONS
· WHISTLEP/TGP Whistle Receipt Nueces Receipt Meter (Pin 54847) - through approx 94% of SIPss increases due to nominations in excess of operational capacity; 31,641 Dths
· AGT/TGP Mendon Mass Tie Over Worche Receipt Meter (Pin 420285) - through 100% of SOP increases receipts due to displacement gas unavailable for backhaul; 2,057 Dths
SEGMENT RESTRICTIONS
· MLV 509 Muskrat Line (Segment 515 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 2,000 Dths
· STA 110 South (Segment 187 BH) - through PIP increases due to scheduled maintenance and nominations in excess of operational capacity
· STA 313Hcg - Z4 Hc (Segment 399 FH) - through PIP increases due to force majeure
LINEPACK RESTRICTIONS
PAYBACK NOMINATIONS WILL BE EVALUATED AT EACH CYCLE AND SCHEDULED ONLY IF OPERATIONALLY FEASIBLE.
STORAGE RESTRICTIONS
· No Authorized Overrun Injections Services under Rate Schedule FS-AO at the following storage fields:
· Northern MA (460018) storage field
· Portland MA (460025) storage field
· Portland PA (460020) storage field
· Bear Creek PA (460017) storage field
· No Interruptible Storage Injection Services under Rate Schedule IS at the following storage fields:
· Northern MA (460018) storage field (IS-MA)
· Bear Creek PA (460017) storage field (IS-PA)
· No Parks or Loan Paybacks under Rate Schedule PAL utilizing the PALD or PAL-AO services
Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under FS-PA storage service only with partner approvals.
**PLEASE NOTE MAXIMUM HOURLY ENTITLEMENTS ("MHE") AND/OR ELAPSED PRO RATA SCHEDULED QUANTITIES ("EPSQ") WILL BE REVIEWED AND MAY BE ENFORCED AT ANY METER DURING INTRADAY OR HOURLY CYCLES.
**FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.
Your session will expire in . Click OK to renew your session.