Effective Evening Cycle (9:00) for the gas day of Saturday, February 08, 2025 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ZONE L AND ZONE 1 ON THE 500 LINE ONLY AND ALL AREAS NORTH OF STA 219 ON THE 200 LINE INCLUDING THE NIAGARA SPUR AND ALL AREAS EAST OF STA 219 ON THE 300 LINE INCLUDING THE HC LINE FOR OVER-TAKES FROM THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
METER RESTRICTIONS
· AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 59% of SIPss increases due to nominations in excess of operational capacity; 32,460 Dths
· Wright Receipt Meter (Pin 412181) - through approx 22% of SIPss increases due to nominations in excess of operational capacity; 208,571 Dths
SEGMENT RESTRICTIONS
· STA 25 (Segment 125 FH) - through 100% of IT increases due to nominations in excess of operational capacity; 11,946 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP increases due to force majeure at STA 860; 10,025 Dths
· STA 87 South 800 Line (Segment 860 BH) - through 100% of IT increases due to scheduled maintenance and nominations in excess of operational capacity; 25 Dths
· STA 307 (Segment 307 BH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 94,925 Dths
· MLV 314 East (Segment 314 BH) - through approx 55% of SOP increases due to nominations in excess of operational capacity; 80,000 Dths
· STA 315 (Segment 315 BH) - through approx 15% of SOP increases due to nominations in excess of operational capacity; 24,920 Dths
· STA 321 (Segment 321 FH) - through 100% of SOP increases due to nominations in excess of operational capacity and due to an emergent repair at STA 323; 679,197 Dths
· STA 325 (Segment 324 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 203,808 Dths
· STA 224 (Segment 224 FH) - through approx 96% of SOP increases due to nominations in excess of operational capacity; 153,670 Dths
· Z5 HC North (Segment 299 FH) - through approx 96% of SOP increases due to nominations in excess of operational capacity; 226,651 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 260,953 Dths
· STA 249 (Segment 249 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 153,940 Dths
· STA 254 (Segment 249 FH) - through approx 96% of SOP increases due to nominations in excess of operational capacity; 123,422 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 109,783 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 163,811 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Nominations for Authorized Overrun Withdrawal Services (FS-AO) at the Northern MA (460018) storage field, the Portland MA (460025) storage field, the Portland PA (460020) storage field or the Bear Creek PA (460017) storage field will not be allowed until further notice. Additionally, customers who elected swing on storage or storage swing options for balancing (SOS or SSO) may only swing up to their Maximum Daily Withdrawal (MDWQ) only until further notice.
Nominations for Firm Storage Flex Authorized Overrun (FSF-AO) Withdrawal Services under Rate Schedule FS-F at the Pine Prairie Virtual Meter (54628) will not be allowed until further notice.
Nominations for Interruptible Storage Withdrawal Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and nominations for Interruptible Storage Withdrawal Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field will not be allowed until further notice.
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017) (IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the (IS-PA, FS-PA) storage services with partner approvals. Additionally, no transfers from IS-MA and IS-PA to FS will be allowed until further notice.
No Loans or Park Withdrawals under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide until further notice.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.