Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  09/07/2022 2:26:19PM Notice End Date/Time:  09/08/2022 9:00:00am
Post Date/Time:  9/7/2022 2:26:19 PM Notice ID: 384203
Reqrd Rsp:  1 Rsp Date:  09/07/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 09-08-2022 TIMELY CYCLE
Notice Text:

Effective Timely Cycle (9:00) for the gas day of September 08, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR SOUTH OF STA 1 FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         MLV 406 (Segment 406 BH) - through approx 28% of PIP due to scheduled maintenance and nominations in excess of operational capacity; 158,182 Dths

·         Transco/TGP Kinder La  Exch (Bi  1 Delivery Meter (Pin 420373) - through 100% of SOP due to operational concerns; 5,000 Dths

·         STA 823 (Segment 823 BH) - through 100% of SOP due to operational concerns; 37,017 Dths

·         Pine Prairie /TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 65% of SOP due to imbalance management quantity exceeded; 265,498 Dths

·         STA 834 (Segment 834 BH) - through approx 31% of SOP due to nominations in excess of operational capacity; 61,186 Dths

·         TGP/SNG Toca Exchange St Bernard Delivery Meter (Pin 420556) - through approx 99% of SOP due to nominations in excess of operational capacity; 20,830 Dths

·         Gulf South/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 50% of SIPps due to imbalance management quantity exceeded; 93,368 Dths

·         Sesh/TGP Petal Interconnect: Rip 53 Delivery Meter (Pin 421059) - through 100% of SOP due to operational concerns; 15 Dths

·         Transco/TGP Heidelberg Mississippi Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 20 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 36% of SIPps due to nominations in excess of operational capacity; 154,576 Dths

·         MLV 548 (Segment 542 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 26,269 Dths

·         Atmos KY/TGP Simpson Delivery Meter (Pin 421000) - through approx 23% of SIPss due to nominations in excess of operational capacity; 114 Dths

·         Hickory/TGP Mohawk Road Power Plt Delivery Meter (Pin 50789) - through approx 96% of PAYBACK TGP due to nominations in excess of operational capacity; 9,570 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP due to the force majeure at MLV 309 to MLV 310; 71,000 Dths

·         STA 313 West (Segment 307 BH) - through 100% of SOP due to the force majeure at MLV 309 to MLV 310; 157,027 Dths

·         MLV 314 East (Segment 314 BH) - through approx 75% of SOP due to nominations in excess of operational capacity; 145,656 Dths

·         STA 315 (Segment 315 BH) - through approx 77% of SOP due to nominations in excess of operational capacity; 556,513 Dths

·         STA 321 (Segment 321 FH) - through approx 50% of SOP due to nominations in excess of operational capacity; 362,808 Dths

·         AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 98% of SOP due to nominations in excess of operational capacity; 221,684 Dths

·         MLV 330 (Segment 324 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 236,023 Dths

·         Z5HC North (Segment 299 FH) - through approx 70% of SOP due to nominations in excess of operational capacity; 539,542 Dths

·         STA 245 (Segment 245 FH) - through approx 76% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 502,625 Dths

·         STA 261 Discharge East (Segment 261 FH) - through approx 14% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 19,765 Dths

·         MLV 273 (Segment 284 FH) - through approx 97% of SOP due to nominations in excess of operational capacity; 262,708 Dths

LINEPACK RESTRICTIONS

No Payback FROM the pipe will be scheduled South of STA 1 in South Texas or South of STA 542 on the 500 until further notice.  PALD and PALAO nominations OFF the system will not be scheduled in these areas.  Additionally, Payback system wide will be evaluated at each cycle and scheduled only if operationally feasible.

STORAGE RESTRICTIONS

NONE

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

....