Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  09/12/2021 3:13:30PM Notice End Date/Time:  12/31/2049 9:00:00AM
Post Date:  9/12/2021 3:13:30 PM Notice ID: 380259
Reqrd Rsp:  1 Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 09-12-2021 ID2
Notice Text:

Effective Intraday 2 Cycle (18:00) for the gas day of September 12, 2021 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL AREAS SOUTH OF STA 9 FOR OVER-TAKES OUT OF THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES and OFO MONTHLY CRITICAL DAY 1 FOR ALL OF ZONE 4 FOR OVER-DELIVERIES INTO THE SYSTEM FOR LMPA AND SA BALANCING PARTIES

RESTRICTIONS

·         STA 823 (Segment 823 BH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 87,241 Dths

·         STA 114 East (Segment 114 BH) - through 100% of PIP increases  due to scheduled maintenance and nominations in excess of operational capacity; 6,058 Dths

·         STA 204 (Segment 204 BH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 10,000 Dths

·         MLV 217 (Segment 217 BH) - through 100% of SOP increases  due to operational concerns; 2,299 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 14,705 Dths

·         MLV 314 East (Segment 314 BH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 47,652 Dths

·         STA 315 (Segment 315 BH) - through approx 71% of SOP increases  due to nominations in excess of operational capacity; 34,782 Dths

·         STA 321 (Segment 321 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 71,116 Dths

·         Z5HC North (Segment 299 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 145,357 Dths

·         STA 245 (Segment 245 FH) - through approx 40% of SOP increases  due to nominations in excess of operational capacity; 73,366 Dths

LINEPACK RESTRICTIONS

Payback nominations FROM the pipe in all areas South of STA 9 as well as Payback nominations TO the pipe in Zone 4 will be evaluated at each cycle and scheduled only if operationally feasible. 

STORAGE RESTRICTIONS

No transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the (IS-PA, FS-PA) storage services with partner approvals.

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.