• Interstate
    • Cheyenne Plains
    • Colorado Interstate Gas
    • Elba Express
    • El Paso Natural Gas
    • Horizon Pipeline
    • KM Illinois Pipeline
    • KM Louisiana Pipeline
    • Midcontinent Express
    • Mojave Pipeline
    • Natural Gas Pipeline
    • Ruby Pipeline
    • Sierrita Gas Pipeline
    • Southern LNG
    • Southern Natural Gas
    • Tennessee Gas Pipeline
    • TransColorado Gas Transmission
    • Wyoming Interstate
    • Young Gas Storage
  • Other
    • Keystone Gas Storage
  • Midstream
    • Banquete Hub
    • Camino Real
    • Copano Pipelines
    • Kinderhawk Field Services
    • KM Boarder Pipeline
    • Eagle Ford Gathering
    • Gulf Coast Express Pipeline
    • KM Mexico Pipeline
    • KM North Texas Pipeline
    • Permian Highway Pipeline
    • KM Tejas Pipeline
    • KM Texas Pipeline
  • Collapse Informational PostingsInformational Postings
    • Expand CapacityCapacity
      • Expand Operationally AvailableOperationally Available
        • Point Capacity
        • Segment Capacity
        • Storage Capacity
      • Expand UnsubscribedUnsubscribed
        • Point Capacity
        • Segment Capacity
        • Storage Capacity
      • Capacity Allocation Log
      • No-Notice Activity
    • Expand Gas QualityGas Quality
      • Tariff Reference
      • Representative Mainline Points
      • Gas Quality Standards
      • Hourly Gas Quality Data
      • Interchangeability Points
      • HDP Blending Points
      • HDP Receipt Points
    • Index of Customers
    • Locations
    • Expand NoticesNotices
      • Critical
      • Non-Critical
      • Planned Service Outage
      • Request to Purchase Releasable Capacity
      • Waste Heat
      • Capacity Release Indices
    • Posted Imbalances
    • Regulatory
    • Expand Standards of ConductStandards of Conduct
      • Affiliate Names & Addresses
      • Affiliate Tariff Waivers
      • Chief Compliance Officer
      • Employee Transfers
      • Implementation Procedures
      • Information Disclosure
      • Job Titles & Descriptions
      • Potential Mergers
      • Shared Facilities
      • Voluntary Consent
    • Expand TariffTariff
      • Title Sheet/Section
      • Table Of Contents
      • Preliminary Statement
      • Expand MapMap
        • Tariff Reference
        • System Map
        • Zone 0
        • Zone L
        • Zone 1
        • Zone 2
        • Zone 3
        • Zone 4
        • Zone 5
        • Zone 6
      • Currently Effective Rates
      • Rate Schedules
      • General Terms and Conditions
      • Form Of Service Agreement
      • Entire Tariff
      • Sheet/Section Index
    • Expand Transactional ReportingTransactional Reporting
      • Firm
      • Interruptible
      • Capacity Release
    • Info Lookup
    • Other
    • Downloads
    • Search
    • Expand Customer ActivitiesCustomer Activities
      • DART Login
    • Site Map
Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  OPERATIONAL FLOW ORDER Notice Type Desc (2):  OFO
Notice Eff Date/Time:  09/01/2021 7:36:56AM Notice End Date/Time:  12/31/2049 9:00:00AM
Post Date:  9/1/2021 7:36:56 AM Notice ID: 380118
Reqrd Rsp:  1 Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  OFOCRITICALDAY1 FOR Z 4,5&6 EFF 9-2-21
Notice Text:
Tennessee anticipates very limited flexibility due to higher pipeline capacity utilization and significantly colder weather this week

OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 4, 5 AND 6 EFFECTIVE 9-2-2021

 

Due to forecasted milder temperatures moving into the Northeast with associated lower demand and in an effort to protect system integrity and firm service obligations, effective for the Gas Day of Thursday, September 2, 2021, and until further notice, Tennessee is implementing an OFO Daily Critical Day 1 for all of Zones 4, 5 and 6 for all Balancing Parties (including LMS-PA, SA contracts acting as balancing parties, LMS-MA, and LMS-PL balancing parties).  This action is pursuant to Article X, Section 4 of the General Terms and Conditions of Tennessee's FERC Gas Tariff. 

 

All delivery point operators in all of Zones 4, 5 and 6 are required to keep actual daily takes out of the system equal to or greater than scheduled quantities regardless of their cumulative imbalance position.  All receipt point operators in all of Zones 4, 5 and 6 are required to keep actual daily receipts into the system equal to or less than scheduled quantities regardless of their cumulative imbalance position.  In addition, it is essential that delivery point operators schedule gas at meters commensurate with takes within the affected areas.  All LMS-PA, SA contracts acting as balancing parties, LMS-MA and LMS-PL Balancing Parties are required to maintain an actual daily flow rate not exceeding 2% of scheduled quantities or 500 dths, whichever is greater for over-deliveries into the system and under-takes from the system. Customers will be assessed a rate of $5.00 plus the applicable Regional Daily Spot Price per dekatherm for that portion of physical quantities related to over-deliveries by receipt point operators and under-takes by delivery point operators which exceed this tolerance.

 

THIS DAILY OFO CRITICAL DAY 1 WILL REMAIN IN EFFECT UNTIL FURTHER NOTICE.  

 

ADDITIONALLY, THE FOLLOWING OFOs REMAINS IN EFFECT UNTIL FURTHER NOTICE:

OFO DAILY CRITICAL DAY 1 FOR ALL AREAS SOUTH OF STA 9 FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

OFO MONTHLY CRITICAL DAY 1 FOR ALL OF ZONE 4 FOR OVER-DELIVERIES INTO THE SYSTEM FOR LMPA AND SA BALANCING PARTIES

 

TENNESSEE WILL INFORM CUSTOMERS BY EBB WHEN THESE OFOS WILL BE LIFTED.

 

Tennessee would like to remind all operators/agents of power plants directly connected to TGP of certain parameters of FERC Order 698 requirements. Tennessee requires that all power plant operators submit burn profiles and nominations prior to gas flow. Due to very limited flexibility, power plant operators are encouraged to burn ratably based on scheduled volumes. The burn profiles should be sent to TGPGasControl@Kindermorgan.com. The latest burn profile template can be found by accessing the Tennessee web site and following the steps below.

 

https://pipeportal.kindermorgan.com/PortalUI/DefaultKM.aspx?TSP=TGPD

Customer Information

Presentations

PowerPlantBurnProfile.xls

 

In the event these OFOs are not sufficient to maintain the operational integrity of the system, Tennessee may escalate to a Critical Day II, an OFO Balancing Alert, Meter Specific OFO(s) or Hourly OFO(s). Tennessee cannot accept unscheduled imbalances and requires all customers to nominate and schedule all payback requests.  Payback nominations in these areas will be evaluated at each cycle and scheduled only if operational feasible.

 

Tennessee will deem all affected Shippers to be in compliance with the actions specified in the Daily Critical Day 1 OFOs if after the measurement close the actual system conditions were opposite to the conditions for which this OFO was issued.

   

Please contact your Scheduler if you have any questions.