Effective Timely Cycle (9:00) for the gas day of April 09, 2021 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS SOUTH OF STA 9 FOR OVER-TAKES OUT OF THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
RESTRICTIONS
· Pemex Lateral (Segment 492 FH) - through approx 98% of SOP due to nominations in excess of operational capacity; 20,483 Dths
· STA 823 (Segment 823 BH) - through approx 68% of SOP due to nominations in excess of operational capacity; 116,721 Dths
· MLV 548 (Segment 542 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 10,283 Dths
· STA 110 South (Segment 187 BH) - through approx 21% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 63,357 Dths
· STA 204 (Segment 204 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 65,756 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 36,213 Dths
· MLV 314 East (Segment 314 BH) - through approx 99% of SOP due to nominations in excess of operational capacity; 209,372 Dths
· STA 315 (Segment 315 BH) - through approx 84% of SOP due to nominations in excess of operational capacity; 268,383 Dths
· STA 321 (Segment 321 FH) - through approx 55% of SOP due to nominations in excess of operational capacity; 404,509 Dths
· STA 325 (Segment 324 FH) - through approx 52% of SOP due to emergent repair; 100,798 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 47% of SIPss due to nominations in excess of operational capacity; 167,363 Dths
· MLV 336 East (Segment 336 FH) - through approx 14% of SOP due to nominations in excess of operational capacity; 16,771 Dths
· STA 224 (Segment 224 BH) - through 100% of SOP due to operational concerns; 59,640 Dths
· Z5HC North (Segment 299 FH) - through approx 82% of SOP due to nominations in excess of operational capacity; 706,175 Dths
· STA 245 (Segment 245 FH) - through approx 57% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 306,177 Dths
· Wright Receipt Meter (Pin 412181) - through 100% of SIPss due to pipeline maintenance at receipt location; 89,750 Dths
· MLV 273 (Segment 284 FH) - through approx 62% of SOP due to nominations in excess of operational capacity; 75,911 Dths
LINEPACK RESTRICTIONS
Payback nominations FROM the pipe in all areas South of STA 9 will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
No transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the (IS-PA, FS-PA) storage services with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.