Effective Intraday 2 Cycle (18:00) for the gas day of October 18, 2020 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY ACTION ALERT FOR ALL OF ZONES L, 1, 2, 4, 5 AND 6 FOR ALL BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM AND UNDER-TAKES OUT OF THE SYSTEM
RESTRICTIONS
· STA 823 Muskrat Line (Segment 509 BH) - through 100% of SOP increases due to operational concerns; 19,039 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 16,000 Dths
· STA 315 (Segment 315 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 9,389 Dths
· Sjrsy Rg/TGP Beirne Hill Sales Brad Delivery Meter (Pin 48061) - through 100% of IT increases due to nominations in excess of operational capacity; 18,263 Dths
· Dominion/TGP Ellisburg Injection Po Receipt Meter (Pin 460012) - through 100% of SOP receipt ncreases due to storage capacity constraint; 5,000 Dths
LINEPACK RESTRICTIONS
Paybacks TO the pipe in Zones L, 1, 2, 4, 5 and 6 will be reviewed at each cycle and scheduled only if operationally feasible. No Parks or Loan Paybacks under Rate Schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide.
STORAGE RESTRICTIONS
No Secondary Receipts from Dominion Ellisburg (460012) or Dominion Harrison (460004).
No transfers from Dominion Ellisburg Storage (460012) or from Dominion Harrison (460004) to TGP Northern Storage (IS-MA, FS-MA).
No Interruptible Storage Injection nominations at the Northern MA (460018) (IS-MA) or Bear Creek PA (460017) (IS-PA) storage fields.
No Authorized Overrun Injections (FS-AO) OR Authorized Overrun Injections above Maximum Daily Injection Quantity (MDIQ) and below Maximum Daily Withdrawal Quantity (MDWQ) at Northern MA (460018), Portland MA (460025), Portland PA (460020) or Bear Creek PA (460017) storage fields until further notice.
No transfers from TGP Bear Creek storage to SNG Bear Creek storage (460017) (IS-PA, FS-PA). Transfers to TGP Bear Creek storage from SNG Bear Creek storage (460017) will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.