Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  06/12/2019 5:41:01PM Notice End Date/Time:  12/31/2049 9:00:00AM
Post Date:  6/12/2019 5:41:01 PM Notice ID: 371736
Reqrd Rsp:  1 Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 6-13-19 TC REVISED
Notice Text:

REVISED

Effective Timely Cycle (9:00) for the gas day of June 13, 2019 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

MONTHLY CRITICAL DAY 1 OFO FOR ZONE 4 FOR ALL LMSPA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM                                    

RESTRICTIONS

·         Pemex Lateral (Segment 492 FH) - through approx 71% of SOP  due to nominations in excess of operational capacity; 1,741 Dths

·         MLV 3 (Segment 101 BH) - through approx 58% of SOP  due to nominations in excess of operational capacity; 2,065 Dths

·         Trnsco/TGP Kinder La  Exch  (Bi  1 Delivery Meter (Pin 420373) - through approx 38% of SOP  due to imbalance management quantity exceeded; 89,383 Dths

·         STA 834 (Segment 834 BH) - through approx 66% of SOP  due to nominations in excess of operational capacity; 89,627 Dths

·         STA 860 (Segment 860 BH) - through approx 78% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 134,038 Dths

·         Trnsco/TGP Heidelberg Delivery Meter (Pin 420291) - through approx 22% of SOP  due to nominations in excess of operational capacity; 3,091 Dths

·         MLV 548 (Segment 542 BH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 13,599 Dths

·         STA 204 (Segment 204 BH) - through approx 83% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 29,630 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 1,100 Dths

·         MLV 314 East (Segment 314 BH) - through 100% of SOP  due to nominations in excess of operational capacity; 269,328 Dths

·         STA 315 (Segment 315 BH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 357,259 Dths

·         STA 321 (Segment 321 FH) - through approx 5% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 19,824 Dths

·         STA 325 (Segment 324 FH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 200,528 Dths

·         Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through 100% of SIPps  due to pipeline maintenance at delivery location; 272,233 Dths

·         Trnsco/TGP Rivervale New Jersey Bergen Delivery Meter (Pin 420101) - through 100% of SIPss  due to nominations in excess of operational capacity; 110,735 Dths

·         STA 224 (Segment 224 FH) / HC Zn 5 (Segment 299 FH) - through approx 40% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 295,266 Dths

·         STA 245 (Segment 245 FH) - through approx 79% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 420,428 Dths

LINEPACK RESTRICTIONS

None

STORAGE RESTRICTIONS

No Interruptible Storage Injection Services (IS-PA) at Bear Creek (460017) or Portland PA (460020).

No transfers from TGP Bear Creek Storage to SNG Bear Creek Storage (IS-PA, FS-PA).

Transfers into TGP Bear Creek from SNG Bear Creek will be allowed under the FS-PA Storage Service ONLY with partner approvals.

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.