Effective Evening Cycle (9:00) for the gas day of March 15, 2019 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
None
Bumped
STA 307 (Segment 307 BH) – through 100% of flowing IT; 434 Dths
RESTRICTIONS
Pemex Lateral (Segment 492 FH) - through approx 99% of SOP EC increases due to nominations in excess of operational capacity; 36,814 Dths
STA 1 (Segment 101 BH) – through 100% of SOP EC increases due to nominations in excess of operational capacity; 3,769 Dths
STA 9 (Segment 109 BH) – through 100% of SOP EC increases due to nominations in excess of operational capacity; 3,710 Dths
STA 224 (Segment 224 FH) / HC Zn 5 (Segment 299 FH) – through approx 49% of SOP EC increases due to nominations in excess of operational capacity; 180,782 Dths
STA 245 (Segment 245 FH) – through approx 59% of SOP EC increases due to nominations in excess of operational capacity; 180,295 Dths
MLV 273 (Segment 284 FH) – through approx 92% of SOP EC increases due to nominations in excess of operational capacity; 76,964 Dths
Arlington Storage Receipt Meter (Pin 412803) – through 100% of IT EC increases due to nominations in excess of operational capacity; 29,784 Dths
White Hollow Receipt Meter (Pin 412805) – through approx 82% of SA EC increases due to nominations in excess of operational capacity; 4,660 Dths
STA 307 (Segment 307 BH) – through 100% of SIPps EC increases due to emergent repair and nominations in excess of operational capacity; 3,275 Dths
MLV 314 (Segment 314 BH) – through 100% of SOP EC increases due to nominations in excess of operational capacity; 148,395 Dths
STA 315 (Segment 315 BH) – through approx 94% of SOP EC increases due to nominations in excess of operational capacity; 242,133 Dths
Mahwah Delivery Meter (Pin 420207) – through approx 80% of SOP EC increases due to nominations in excess of operational capacity; 50,306 Dths
LINEPACK RESTRICTIONS
No park withdrawals or loans under rate schedule PAL will be allowed utilizing the PAL-D or PAL-AO services system wide until further notice
STORAGE RESTRICTIONS
No Authorized Overrun Storage Withdrawals (FSMA-AO, FSPA-AO) accepted from Northern (460018), Portland Storage MA (460025), Portland Storage PA (460020) or Bear Creek Storage (460017)
No Interruptible Storage Withdrawals (ISMA, ISPA) accepted from Northern (460018), Portland Storage MA (460025), Portland Storage PA (460020) or Bear Creek Storage (460017)
No transfers from TGP Bear Creek Storage to SNG Bear Creek Storage (IS-PA, FS-PA)
Transfers into TGP Bear Creek from SNG Bear Creek will be allowed with partner approvals
Customers who elected swing on storage (SSO) or storage swing options (SSO) may swing up to their Maximum Daily Withdrawal Quantity (MDWQ) only
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND
ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED
SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.