Notice Detail
           
Return To Results
TSP/TSP Name:  6914865-COLORADO INTERSTATE GAS CO. Critical: Y
Notice Type Desc (1):  MAINTENANCE Notice Type Desc (2):  MAINTENANCE
Notice Eff Date/Time:  10/20/2020 2:50:31PM Notice End Date/Time:  11/19/2020 9:00:00am
Post Date/Time:  10/20/2020 2:50:31 PM Notice ID: 119579
Reqrd Rsp:  1 Rsp Date:  10/20/2020
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  Operations Planning Report November 2020
Notice Text:

Colorado Interstate Gas Company

Operations Planning Report for November 2020

Issued October 20, 2020

COLORADO INTERSTATE GAS COMPANY MAINTENANCE

Wyoming: None of the planned maintenance is expected to impact service

Colorado:

1. Crazy Horse to Cheyenne Lat (Segment 192): Fort Lupton Compressor Station CIG will be performing Station maintenance November 16 through November 20. This outage results in the following impacts.

Operating Capacity

Capacity Reduction

Limit MDth/d

Limit MDth/d

Nov 16 thru Nov 19

409

326

Nov 20 Cycles 1 thru 4

409

326

Nov 20 Cycle 5

409

   364**

** The nomination limit for this cycle has been prorated for the remaining time in the gas day.

Storage inventory is projected to be within normal guidelines on November 1.

Field   

Max Inject MMcf/d

 Max. Withdraw MMcf/d

Boehm

35,000

124,000

Flank

50,000

164,000

Ft. Morgan

90,000

450,000

Latigo

50,000

139,000

Totals

225,000

877,000

Note to storage table: Maximum injection and withdrawal figures are based upon projections for gas-in-place on November 1, 2020. Departure from these projections can affect injection and withdrawal capabilities. Thermal quantities related to storage field transactions are determined based upon an average of 1064 Btu/cf.

CIG Services Utilizing Young Gas Storage Company

Young Gas Storage Company (Young) will be conducting scheduled reservoir maintenance beginning on November 3 through November 10. Please refer to the Young EBB posting #119538 and associated notices.  This maintenance is to test the reservoir's integrity and to ensure the continued safe and reliable operations of the field.  During the test period, no injections or withdrawals will be supported.  This capacity outage will impact the following Young interconnect locations; PIN ID 800826 (YCS) and PIN ID 800077 (BCS) with Colorado Interstate Gas Company.

No Planning Meeting Scheduled

No requests for a Joint Monthly Operating Plan Meeting have been received by CIG. Therefore, pursuant to Section 11.1 of General Terms and Conditions of the FERC Gas Tariff, no such meetings have been scheduled. If at any time there are any questions regarding operational issues, do not hesitate to call Bill McMillan at (719)520-4389.

Any comments or questions about this report should be directed to Glen Petty (719) 520-4704 or Bill McMillan (719) 520-4389.

 

....