Effective Evening Cycle (9:00) for the gas day of February 20, 2023 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
NONE
RESTRICTIONS
· STA 9 (Segment 109 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 113,640 Dths
· Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 4% of SOP increases due to operational concerns; 3,208 Dths
· STA 834 (Segment 834 BH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 182,569 Dths
· Gulfsth/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 39% of SOP increases due to operational concerns; 13,888 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 52% of SIPps increases due to nominations in excess of operational capacity; 38,839 Dths
· STA 110 South (Segment 187 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 71,856 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP increases due to force majeure at MLV 309 to MLV 310; 22,526 Dths
· STA 315 (Segment 315 BH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 217,676 Dths
· STA 321 (Segment 321 FH) - through approx 89% of SOP increases due to nominations in excess of operational capacity; 416,129 Dths
· MLV 336 East (Segment 336 FH) - through approx 17% of SOP increases due to nominations in excess of operational capacity; 1,027 Dths
· Z5HC North (Segment 299 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 413,606 Dths
· STA 245 (Segment 245 FH) - through approx 99% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 371,221 Dths
· MLV 273 (Segment 284 FH) - through approx 97% of SOP increases due to nominations in excess of operational capacity; 85,878 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017) (IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.