Effective Timely Cycle (9:00) for the gas day of February 17, 2023 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
NONE
RESTRICTIONS
· Trnsco/TGP Kinder La Exch (Bi 1 Delivery Meter (Pin 420373) - through 100% of SOP due to operational concerns; 2,048 Dths
· MLV 509 (Segment 509 BH) - through 100% of SOP due to nominations in excess of operational capacity; 7,682 Dths
· STA 823 (Segment 823 BH) - through approx 95% of SOP due to nominations in excess of operational capacity; 21,754 Dths
· STA 834 (Segment 834 BH) - through approx 39% of SOP due to nominations in excess of operational capacity; 81,308 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 53% of SIPps due to nominations in excess of operational capacity; 225,242 Dths
· STA 110 South (Segment 187 BH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 90,751 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to the force majeure at MLV 309 to MLV 310; 36,414 Dths
· MLV 314 East (Segment 314 BH) - through approx 92% of SOP due to nominations in excess of operational capacity; 243,626 Dths
· STA 315 (Segment 315 BH) - through approx 78% of SOP due to nominations in excess of operational capacity; 406,109 Dths
· STA 321 (Segment 321 FH) - through approx 86% of SOP due to nominations in excess of operational capacity; 956,828 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 57% of SOP due to nominations in excess of operational capacity; 70,125 Dths
· Trnsco/TGP Rivervale New Jersey Ber Delivery Meter (Pin 420101) - through approx 5% of SOP due to nominations in excess of operational capacity; 6,149 Dths
· MLV 336 East (Segment 336 FH) - through approx 88% of SOP due to nominations in excess of operational capacity; 100,099 Dths
· Z5HC North (Segment 299 FH) - through approx 92% of SOP due to nominations in excess of operational capacity; 825,680 Dths
· STA 245 (Segment 245 FH) - through approx 95% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 604,743 Dths
· MLV 256 East (Segment 256 FH) - through approx 13% of SOP due to nominations in excess of operational capacity; 18,089 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 54% of SOP due to nominations in excess of operational capacity; 84,679 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP due to nominations in excess of operational capacity; 124,512 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017) (IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.