Effective Evening Cycle (9:00) for the gas day of January 22, 2023 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

NONE

RESTRICTIONS

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 53% of SOP increases  due to operational concerns; 58,845 Dths

·         STA 834 (Segment 834 BH) - through approx 58% of SOP increases  due to nominations in excess of operational capacity; 70,932 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  due to operational concerns; 10 Dths

·         MLV 314 East (Segment 314 BH) - through approx 75% of SOP increases  due to nominations in excess of operational capacity; 67,584 Dths

·         STA 315 (Segment 315 BH) - through approx 37% of SOP increases  due to nominations in excess of operational capacity; 54,096 Dths

·         STA 321 (Segment 321 FH) - through approx 94% of SOP increases  due to nominations in excess of operational capacity; 467,023 Dths

·         Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 50% of SOP increases  due to nominations in excess of operational capacity; 85,429 Dths

·         MLV 336 East (Segment 336 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 50,637 Dths

·         Z5HC North (Segment 299 FH) - through approx 99% of SOP increases  due to nominations in excess of operational capacity; 350,626 Dths

·         STA 245 (Segment 245 FH) - through approx 92% of SOP increases  due to nominations in excess of operational capacity; 231,739 Dths

·         MLV 256 East (Segment 256 FH) - through approx 15% of SOP increases  due to nominations in excess of operational capacity; 12,845 Dths

·         STA 261 Discharge East (Segment 261 FH) - through approx 73% of SOP increases  due to nominations in excess of operational capacity; 42,633 Dths

·         MLV 273 (Segment 284 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 54,512 Dths

LINEPACK RESTRICTIONS

Payback will be evaluated at each cycle and scheduled only if operationally feasible.

STORAGE RESTRICTIONS

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

 

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

..