Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  01/13/2023 11:03:01AM Notice End Date/Time:  01/14/2023 9:00:00am
Post Date/Time:  1/13/2023 11:03:01 AM Notice ID: 385616
Reqrd Rsp:  1 Rsp Date:  01/13/2023
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 01-13-2023 ID1
Notice Text:

Effective Intraday 1 Cycle (14:00) for the gas day of January 13, 2023 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

NONE

RESTRICTIONS

·         Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through 100% of IT increases  due to imbalance management; 19,878 Dths

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 35% of SOP increases  due to operational concerns; 36,849 Dths

·         STA 834 (Segment 834 BH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 69,283 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  due to operational concerns; 10 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 99% of SIPps increases  due to nominations in excess of operational capacity; 59,697 Dths

·         STA 860 South 500 Line (Segment 548 BH) - through 100% of IT increases  due to scheduled maintenance and emergent repair at STA 555 Unit 4A; 2,866 Dths

·         MLV 314 East (Segment 314 BH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 147,217 Dths

·         STA 321 (Segment 321 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 345,655 Dths

·         Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 16% of SOP increases  due to nominations in excess of operational capacity; 19,891 Dths

·         MLV 336 East (Segment 336 FH) - through approx 99% of SOP increases  due to nominations in excess of operational capacity; 57,542 Dths

·         Z5HC North (Segment 299 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 277,166 Dths

·         STA 245 (Segment 245 FH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 343,328 Dths

·         MLV 273 (Segment 284 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 48,520 Dths

LINEPACK RESTRICTIONS

Payback will be evaluated at each cycle and scheduled only  if operationally feasible.

STORAGE RESTRICTIONS

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

 

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

...