Effective Timely Cycle (9:00) for the gas day of January 02, 2023 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO CRITICAL DAY 1 SYSTEM WIDE FOR ALL OF ZONES 0, L, 1, 2, 3, 4, 5, AND 6 FOR ALL BALANCING PARTIES (INCLUDING LMS-PA, SA CONTRACTS ACTING AS BALANCING PARTIES AND LMS-MA BALANCING PARTIES).
RESTRICTIONS
· Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through approx 65% of SIPsp due to imbalance management; 69,590 Dths
· Net Mexi/TGP Gillrina Road Nueces Delivery Meter (Pin 47799) - through 100% of SA receipts due to operational concerns; 5,800 Dths
· Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 50% of SOP due to operational concerns; 112,693 Dths
· STA 834 (Segment 834 BH) - through approx 59% of SOP due to nominations in excess of operational capacity; 132,511 Dths
· Gulfsth/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 99% of SIPss due to operational concerns; 12,492 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 13% of SIPps due to nominations in excess of operational capacity; 28,199 Dths
· Atmos Ky/TGP Campbellsville Ky Tayl Delivery Meter (Pin 420010) - through approx 1% of SIPps due to nominations in excess of operational capacity; 104 Dths
· MLV 314 East (Segment 314 BH) - through approx 87% of SOP due to nominations in excess of operational capacity; 107,742 Dths
· STA 315 (Segment 315 BH) - through approx 92% of SOP due to nominations in excess of operational capacity; 481,691 Dths
· Debm/TGP Beirne Hill Sales Bradford Delivery Meter (Pin 48061) - through approx 39% of IT due to nominations in excess of operational capacity; 24,347 Dths
· STA 321 (Segment 321 FH) - through approx 78% of SOP due to nominations in excess of operational capacity; 714,277 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 90% of SOP due to nominations in excess of operational capacity; 180,216 Dths
· MLV 336 East (Segment 336 FH) - through approx 73% of SOP due to nominations in excess of operational capacity; 45,298 Dths
· MLV 355 (Segment 355 BH) - through 100% of SOP due to operational concerns; 20,036 Dths
· Z5HC North (Segment 299 FH) - through approx 91% of SOP due to nominations in excess of operational capacity; 804,102 Dths
· STA 245 (Segment 245 FH) - through approx 93% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 711,242 Dths
· MLV 273 (Segment 284 FH) - through approx 84% of SOP due to nominations in excess of operational capacity; 103,895 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and only scheduled if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.