Effective Timely Cycle (9:00) for the gas day of December 29, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
NONE
RESTRICTIONS
· Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through approx 72% of SIPss due to imbalance management; 31,929 Dths
· MLV 707 East - Carthage Lateral (Segment 700 FH) - through approx 6% of SA due to nominations in excess of operational capacity; 7,187 Dths
· Cabot/TGP St Mary Carbon Black: Dip Delivery Meter (Pin 421080) - through approx 2% of PAYBACK TGP due to nominations in excess of operational capacity; 163 Dths
· Pine Pra/TGP Pine Prairie North Rap Receipt Meter (Pin 421043) - through approx 12% of IT due to operational concerns; 14,311 Dths
· STA 834 (Segment 834 BH) - through approx 17% of SOP due to nominations in excess of operational capacity; 23,030 Dths
· Gulfsth/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 80% of SOP due to operational concerns; 12,960 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 26% of SIPps due to nominations in excess of operational capacity; 69,409 Dths
· STA 313 West (Segment 307 BH) - through 100% of SOP due to force majeure at MLV 309 to MLV 310; 41,677 Dths
· MLV 314 East (Segment 314 BH) - through approx 52% of SOP due to nominations in excess of operational capacity; 88,565 Dths
· STA 315 (Segment 315 BH) - through approx 54% of SOP due to nominations in excess of operational capacity; 222,904 Dths
· Debm/TGP Beirne Hill Sales Bradford Delivery Meter (Pin 48061) - through approx 70% of IT due to nominations in excess of operational capacity; 6,872 Dths
· STA 321 (Segment 321 FH) - through approx 86% of SOP due to nominations in excess of operational capacity; 886,629 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 86% of SOP due to nominations in excess of operational capacity; 253,444 Dths
· MLV 336 East (Segment 336 FH) - through approx 76% of SOP due to nominations in excess of operational capacity; 43,599 Dths
· MLV 355 (Segment 355 BH) - through 100% of SOP due to operational concerns; 71,484 Dths
· Z5HC North (Segment 299 FH) - through approx 95% of SOP due to nominations in excess of operational capacity; 877,291 Dths
· STA 245 (Segment 245 FH) - through approx 99% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 622,980 Dths
· MLV 256 East (Segment 256 FH) - through approx 13% of SOP due to nominations in excess of operational capacity; 24,893 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 34% of SOP due to nominations in excess of operational capacity; 62,827 Dths
· MLV 273 (Segment 284 FH) - through approx 82% of SOP due to nominations in excess of operational capacity; 125,947 Dths
· STA 268 North(Segment 268 FH) - through 100% of SOP due to nominations in excess of operational capacity; 2,909 Dths
LINEPACK RESTRICTIONS
Payback will be evaluated at each cycle and only scheduled if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.