Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  12/27/2022 2:50:42PM Notice End Date/Time:  12/28/2022 9:00:00am
Post Date/Time:  12/27/2022 2:50:42 PM Notice ID: 385439
Reqrd Rsp:  1 Rsp Date:  12/27/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 12-28-2022 TIMELY CYCLE
Notice Text:

Effective Timely Cycle (9:00) for the gas day of December 28, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO BALANCING ALERT METER SPECIFIC FOR PIN 420803 FOR OVER-TAKES FROM THE SYSTEM and OFO DAILY BALANCING ALERT FOR ALL OF ZONE 4 FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES and OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES L, 1 AND 2 FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR LMPAS, SAs ACTING AS BALANCING PARTIES, AND LMMAS and OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 3, 5 AND 6 FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

RESTRICTIONS

·         Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through approx 64% of SIPss  due to imbalance management; 34,472 Dths

·         STA 40 South Of Carthage (Segment 132 FH) - through approx 11% of SA  due to operational concerns; 36,084 Dths

·         Etng/TGP East Lobelville Tn Perry Delivery Meter (Pin 420042) - through 100% of SOP  due to operational concerns; 12,704 Dths

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 44% of SOP  due to operational concerns; 92,963 Dths

·         STA 834 (Segment 834 BH) - through approx 13% of SOP  due to nominations in excess of operational capacity; 15,503 Dths

·         Greenbrier Tn 2 (Dual) Delivery Meter (Pin 420289) - through 100% of SOP  due to operational concerns; 32,945 Dths

·         Midwstrn/TGP Mgt Sms Sumner Delivery Meter (Pin 420852) - through approx 22% of IT  due to operational concerns; 21,277 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps  due to operational concerns; 10 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 26% of SIPps  due to nominations in excess of operational capacity; 68,314 Dths

·         Atmos Ky/TGP Harrodsburg Ky Boyle Delivery Meter (Pin 420028) - through approx 70% of SOP  due to nominations in excess of operational capacity; 3,399 Dths

·         Atmos Ky/TGP Danville Ky Boyle Delivery Meter (Pin 400462) - through approx 11% of SIPss  due to nominations in excess of operational capacity; 1,024 Dths

·         Tet/TGP Hanging Rock Scioto Delivery Meter (Pin 421018) - through 100% of SIPss  due to operational concerns; 93,537 Dths

·         Utica Eo/TGP Kensington Dehy: Rip 2 Receipt Meter (Pin 412868) - through 100% of SA  due to operational concerns; 16,000 Dths

·         MLV 314 East (Segment 314 BH) - through approx 4% of SOP  due to nominations in excess of operational capacity; 8,174 Dths

·         STA 315 (Segment 315 BH) - through approx 25% of SOP  due to nominations in excess of operational capacity; 99,564 Dths

·         Debm/TGP Beirne Hill Sales Bradford Delivery Meter (Pin 48061) - through approx 14% of SOP  due to nominations in excess of operational capacity; 30,273 Dths

·         STA 321 (Segment 321 FH) - through approx 92% of SOP  due to nominations in excess of operational capacity; 902,047 Dths

·         Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through 100% of SOP  due to operational concerns; 301,530 Dths

·         MLV 336 East (Segment 336 FH) - through 100% of SOP  due to nominations in excess of operational capacity; 18,701 Dths

·         MLV 355 (Segment 355 BH) - through 100% of SOP  due to operational concerns; 74,916 Dths

·         Z5HC North (Segment 299 FH) - through approx 95% of SOP  due to nominations in excess of operational capacity; 930,214 Dths

·         STA 245 (Segment 245 FH) - through approx 95% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 402,603 Dths

·         Wright Receipt Meter (Pin 412181) - through approx 33% of SIPss  due to nominations in excess of operational capacity; 174,846 Dths

·         MLV 256 East (Segment 256 FH) - through approx 10% of SOP  due to nominations in excess of operational capacity; 14,847 Dths

·         STA 261 Discharge East (Segment 261 FH) - through approx 24% of SOP  due to nominations in excess of operational capacity; 26,985 Dths

·         MLV 273 (Segment 284 FH) - through approx 77% of SOP  due to nominations in excess of operational capacity; 94,966 Dths

·         STA 268 North(Segment 268 FH) - through 100% of SOP  due to nominations in excess of operational capacity; 2,843 Dths

LINEPACK RESTRICTIONS

Payback OFF the pipe will be evaulated at each cycle and only scheduled if operationally feasible.

STORAGE RESTRICTIONS

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

 

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

..