Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  12/23/2022 11:55:04AM Notice End Date/Time:  12/24/2022 9:00:00am
Post Date/Time:  12/23/2022 11:55:04 AM Notice ID: 385385
Reqrd Rsp:  1 Rsp Date:  12/23/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 12-23-22 ID1
Notice Text:

Effective Intraday 1 Cycle (14:00) for the gas day of December 23, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 0, L, 1 AND 2 FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR LMPAS, SAs ACTING AS BALANCING PARTIES, AND LMMAS

OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 3, 4, 5 AND 6 FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

RESTRICTIONS

·         STA 47 (Segment 143 FH) - through approx 86% of SOP increases due to nominations in excess of operational capacity; 343,044 Dths

·         STA 847 (Segment 847 FH) - through 100% of IT increases due to nominations in excess of operational capacity; 249,120 Dths

·         Transco/TGP Heidelberg Mississippi Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 98% of SIPss increases due to nominations in excess of operational capacity; 3,553 Dths

·         TET/TGP Hanging Rock Scioto Delivery Meter (Pin 421018) - through 100% of SOP increases due to nominations in excess of operational capacity; 4,530 Dths

·         STA 313 West (Segment 307 BH) - through 100% of SOP increases due to the force majeure at MLV 309 to MLV 310; 38,800 Dths

·         MLV 314 East (Segment 314 BH) - through 100% of SOP increases due to nominations in excess of operational capacity; 29,073 Dths

·         STA 315 (Segment 315 BH) - through approx 79% of SOP increases due to nominations in excess of operational capacity; 105,054 Dths

·         STA 321 (Segment 321 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 682,891 Dths

·         AGT/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 75% of SOP increases due to nominations in excess of operational capacity; 97,169 Dths

·         Z5HC North (Segment 299 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 603,105 Dths

·         STA 245 (Segment 245 FH) - through 100% of SIPps increases due to scheduled maintenance and nominations in excess of operational capacity; 197,330 Dths

·         Wright Receipt Meter (Pin 412181) - through approx 78% of SIPss increases due to nominations in excess of operational capacity; 76,239 Dths

·         MLV 256 East (Segment 256 FH) - through approx 90% of SOP increases due to nominations in excess of operational capacity; 47,133 Dths

·         MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 43,868 Dths

·         STA 268 North(Segment 268 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 34 Dths

LINEPACK RESTRICTIONS

Payback OFF the pipe will not be scheduled SYSTEM WIDE. 

STORAGE RESTRICTIONS

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017) (IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

....