Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  12/20/2022 3:30:32PM Notice End Date/Time:  12/21/2022 9:00:00am
Post Date/Time:  12/20/2022 3:30:32 PM Notice ID: 385355
Reqrd Rsp:  1 Rsp Date:  12/20/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 12-20-2022 ID2
Notice Text:

Effective Intraday 2 Cycle (18:00) for the gas day of December 20, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 325 ON THE 300 LINE ONLY FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES

RESTRICTIONS

·         Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through 100% of SA increases  due to imbalance management quantity exceeded; 5,421 Dths

·         STA 47 (Segment 143 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 10,877 Dths

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 25% of SOP increases  due to operational concerns; 18,299 Dths

·         STA 834 (Segment 834 BH) - through approx 96% of SOP increases  due to nominations in excess of operational capacity; 55,151 Dths

·         Gulfsth/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 49% of SOP increases  due to operational concerns; 4,685 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  due to operational concerns; 10 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through 100% of SIPps increases  due to nominations in excess of operational capacity; 14,624 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP increases  due to force majeure at MLV 309 to MLV 310; 5,000 Dths

·         MLV 314 East (Segment 314 BH) - through approx 86% of SOP increases  due to nominations in excess of operational capacity; 45,581 Dths

·         STA 315 (Segment 315 BH) - through approx 56% of SOP increases  due to nominations in excess of operational capacity; 75,088 Dths

·         Debm/TGP Beirne Hill Sales Bradford Delivery Meter (Pin 48061) - through approx 36% of SOP increases  due to nominations in excess of operational capacity; 13,760 Dths

·         STA 321 (Segment 321 FH) - through approx 85% of SOP increases  due to nominations in excess of operational capacity; 303,983 Dths

·         STA 325 (Segment 324 FH) - through 100% of PIP increases  due to force majeure between STA 325 to MLV 329; 57,291 Dths

·         Z5HC North (Segment 299 FH) - through approx 99% of SOP increases  due to nominations in excess of operational capacity; 504,904 Dths

·         STA 245 (Segment 245 FH) - through 100% of PIP increases  due to scheduled maintenance and nominations in excess of operational capacity; 226,291 Dths

·         MLV 273 (Segment 284 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 52,229 Dths

LINEPACK RESTRICTIONS

Payback OFF the pipe will not be scheduled for all areas East of STA 325 on the 300 Line only.  All payback in other areas will be evaluated at each cycle and scheduled only if operationally feasible.

STORAGE RESTRICTIONS

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

 

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

...