Effective Timely Cycle (9:00) for the gas day of December 13, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 321 AND STA 245 FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
RESTRICTIONS
· Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through approx 36% of SIPss due to imbalance management; 15,533 Dths
· Vcp/TGP Valley Crossing Allocation Receipt Meter (Pin 53608) - through 100% of SA due to operational concerns; 653 Dths
· Net Mexi/TGP Gillrina Road Nueces Receipt Meter (Pin 47799) - through 100% of SA due to operational concerns; 2,400 Dths
· Etp/TGP Shoup Nueces Receipt Meter (Pin 412669) - through 100% of SA due to operational concerns; 2,800 Dths
· Entrprse/TGP Agua Dulce Nueces Receipt Meter (Pin 411306) - through 100% of SA due to operational concerns; 1 Dths
· STA 40 South Of Carthage (Segment 132 FH) - through approx 33% of SA due to operational concerns; 134,300 Dths
· Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 51% of SOP due to operational concerns; 151,628 Dths
· STA 834 (Segment 834 BH) - through approx 38% of SOP due to nominations in excess of operational capacity; 61,027 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP due to scheduled maintenance, nominations in excess of operational capacity and emergent repair at STA 860; 10,245 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 29% of SIPps due to nominations in excess of operational capacity; 81,270 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to force majeure at MLV 309 to MLV 310; 10,000 Dths
· MLV 314 East (Segment 314 BH) - through approx 70% of SOP due to nominations in excess of operational capacity; 201,958 Dths
· STA 315 (Segment 315 BH) - through approx 64% of SOP due to nominations in excess of operational capacity; 343,695 Dths
· Debm/TGP Beirne Hill Sales Bradford Delivery Meter (Pin 48061) - through approx 31% of IT due to nominations in excess of operational capacity; 49,062 Dths
· STA 321 (Segment 321 FH) - through approx 82% of SOP due to nominations in excess of operational capacity; 747,085 Dths
· STA 325 (Segment 324 FH) - through approx 16% of SIPsp due to force majeure between STA 325 to MLV 329; 141,103 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 64% of SOP due to nominations in excess of operational capacity; 167,242 Dths
· Z5HC North (Segment 299 FH) - through approx 96% of SOP due to nominations in excess of operational capacity; 849,428 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 586,055 Dths
· Wright Receipt Meter (Pin 412181) - through approx 42% of SIPss due to nominations in excess of operational capacity; 83,495 Dths
· MLV 256 East (Segment 256 FH) - through approx 75% of SOP due to nominations in excess of operational capacity; 148,429 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 55% of SOP due to nominations in excess of operational capacity; 58,102 Dths
· MLV 273 (Segment 284 FH) - through approx 68% of SOP due to nominations in excess of operational capacity; 61,149 Dths
· STA 268 North(Segment 268 FH) - through 100% of SOP due to nominations in excess of operational capacity; 8,402 Dths
LINEPACK RESTRICTIONS
Payback OFF the pipe will not be scheduled for all areas East of STA 321 and STA 245. All payback in other areas will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.