Effective Timely Cycle (9:00) for the gas day of December 12, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 321 AND STA 245 FOR OVER-TAKES OUT OF THE SYSTEM OR UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
RESTRICTIONS
· Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through approx 87% of SIPss due to imbalance management quantity exceeded; 52,304 Dths
· Vcp/TGP Valley Crossing Allocation Receipt Meter (Pin 53608) - through 100% of SA due to operational concerns; 44,100 Dths
· Net Mexi/TGP Gillrina Road Nueces Receipt Meter (Pin 47799) - through 100% of SOP due to operational concerns; 12,387 Dths
· Etp/TGP Shoup Nueces Receipt Meter (Pin 412669) - through 100% of SA due to operational concerns; 8,000 Dths
· Entrprse/TGP Agua Dulce Nueces Receipt Meter (Pin 411306) - through 100% of SA due to operational concerns; 1 Dths
· Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 49% of SOP due to operational concerns; 141,472 Dths
· STA 834 (Segment 834 BH) - through approx 43% of SOP due to nominations in excess of operational capacity; 71,251 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP due to scheduled maintenance and emergent repair at STA 860; 11,737 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps due to operational concerns; 10 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 26% of SIPps due to nominations in excess of operational capacity; 68,821 Dths
· STA 307 (Segment 307 BH) - through 100% of SOP due to force majeure at MLV 309 to MLV 310; 10,000 Dths
· MLV 314 East (Segment 314 BH) - through approx 69% of SOP due to nominations in excess of operational capacity; 201,213 Dths
· STA 315 (Segment 315 BH) - through approx 63% of SOP due to nominations in excess of operational capacity; 341,723 Dths
· Debm/TGP Beirne Hill Sales Bradford Delivery Meter (Pin 48061) - through approx 63% of IT due to nominations in excess of operational capacity; 51,680 Dths
· STA 321 (Segment 321 FH) - through approx 76% of SOP due to nominations in excess of operational capacity; 593,550 Dths
· STA 325 (Segment 324 FH) - through 100% of SIPps due to force majeure between STA 325 to MLV 329; 68,227 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 53% of SOP due to nominations in excess of operational capacity; 127,706 Dths
· Z5HC North (Segment 299 FH) - through approx 95% of SOP due to nominations in excess of operational capacity; 825,509 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP due to scheduled maintenance and nominations in excess of operational capacity; 660,555 Dths
· Wright Receipt Meter (Pin 412181) - through approx 76% of SIPss due to nominations in excess of operational capacity; 175,367 Dths
· MLV 256 East (Segment 256 FH) - through approx 54% of SOP due to nominations in excess of operational capacity; 64,496 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 43% of SOP due to nominations in excess of operational capacity; 42,875 Dths
· MLV 273 (Segment 284 FH) - through approx 74% of SOP due to nominations in excess of operational capacity; 69,082 Dths
· STA 268 North(Segment 268 FH) - through 100% of SOP due to nominations in excess of operational capacity; 11,823 Dths
LINEPACK RESTRICTIONS
Payback OFF the pipe will not be scheduled for all areas East of STA 321 and STA 245. All payback in other areas will be evaluated at each cycle and scheduled only if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.