Effective Intraday 1 Cycle (14:00) for the gas day of November 20, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 321 AND ALL AREAS EAST OF STA 245 FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
RESTRICTIONS
· Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through 100% of PS PAYBACK T increases due to operational concerns; 3,000 Dths
· Vcp/TGP Valley Crossing Allocation Receipt Meter (Pin 53608) - through 100% of SA increases due to operational concerns; 84,763 Dths
· Net Mexi/TGP Gillrina Road Nueces Receipt Meter (Pin 47799) - through 100% of SA increases due to operational concerns; 15,000 Dths
· STA 823 (Segment 823 BH) - through approx 84% of SOP increases due to nominations in excess of operational capacity; 22,080 Dths
· Pine Pra/TGP Pine Prairie North Rap Receipt Meter (Pin 421043) - through approx 18% of SA increases due to imbalance management quantity exceeded; 32,578 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP increases due to scheduled maintenance and emergent repair at STA 860; 9,769 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through 100% of SIPss increases due to nominations in excess of operational capacity; 2,791 Dths
· MLV 314 East (Segment 314 BH) - through approx 30% of SOP increases due to nominations in excess of operational capacity; 14,207 Dths
· STA 315 (Segment 315 BH) - through approx 55% of SOP increases due to nominations in excess of operational capacity; 57,933 Dths
· STA 321 (Segment 321 FH) - through approx 82% of SOP increases due to nominations in excess of operational capacity; 151,207 Dths
· Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 73% of SOP increases due to nominations in excess of operational capacity; 156,976 Dths
· MLV 336 East (Segment 336 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 28,819 Dths
· STA 224 (Segment 224 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 41,340 Dths
· Z5HC North (Segment 299 FH) - through approx 99% of SOP increases due to nominations in excess of operational capacity; 168,168 Dths
· STA 245 (Segment 245 FH) - through 100% of PIP increases due to scheduled maintenance and emergent repair at STA 245 Unit 1C; 185,145 Dths
· Wright Receipt Meter (Pin 412181) - through approx 10% of PIP increases due to nominations in excess of operational capacity; 201,135 Dths
· MLV 256 East (Segment 256 FH) - through approx 45% of SOP increases due to nominations in excess of operational capacity; 35,029 Dths
· STA 261 Discharge East (Segment 261 FH) - through approx 47% of SOP increases due to nominations in excess of operational capacity; 16,910 Dths
· Dynegy/TGP Blackstone Worchester Delivery Meter (Pin 420894) - through approx 94% of IT increases due to nominations in excess of operational capacity; 14,074 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 21,427 Dths
· STA 268 North(Segment 268 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 11,202 Dths
LINEPACK RESTRICTIONS
Payback to Tennessee will be evaluated at each cycle and scheduled if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.