Effective Intraday 2 Cycle (18:00) for the gas day of November 18, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL AREAS EAST OF STA 321 AND ALL AREAS EAST OF STA 245 FOR OVER-TAKES FROM THE SYSTEM AND UNDER-DELIVERIES INTO THE SYSTEM FOR ALL BALANCING PARTIES
RESTRICTIONS
· Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 53% of SOP increases due to imbalance management quantity exceeded; 58,831 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP increases due to scheduled maintenance and emergent repair at STA 860; 54,329 Dths
· TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through 100% of SIPps increases due to nominations in excess of operational capacity; 5,842 Dths
· Tet/TGP Hanging Rock Scioto Delivery Meter (Pin 421018) - through approx 45% of SOP increases due to nominations in excess of operational capacity; 6,615 Dths
· STA 315 (Segment 315 BH) - through approx 91% of SOP increases due to nominations in excess of operational capacity; 106,927 Dths
· MLV 336 East (Segment 336 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 28,819 Dths
· STA 224 (Segment 224 FH) - through approx 87% of SOP increases due to nominations in excess of operational capacity; 46,883 Dths
· Z5HC North (Segment 299 FH) - through approx 80% of SOP increases due to nominations in excess of operational capacity; 94,228 Dths
· STA 245 (Segment 245 FH) - through 100% of PIP increases due to emergent repair at STA 245 Unit 1C; 160,442 Dths
· Wright Receipt Meter (Pin 412181) - through approx 27% of SOP increases due to nominations in excess of operational capacity; 15,165 Dths
· MLV 273 (Segment 284 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 25,859 Dths
LINEPACK RESTRICTIONS
Payback to Tennessee will be evaluated at each cycle and scheduled if operationally feasible.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.