Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  11/10/2022 3:29:45PM Notice End Date/Time:  11/11/2022 9:00:00am
Post Date/Time:  11/10/2022 3:29:45 PM Notice ID: 384925
Reqrd Rsp:  1 Rsp Date:  11/10/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 11-10-2022 ID2
Notice Text:

Effective Intraday 2 Cycle (18:00) for the gas day of November 10, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 0 (EXCLUDING AREAS SOUTH OF STA 1), L, 1, AND 2 FOR OVER-DELIVERIES INTO THE SYSTEM OR UNDER-TAKES OUT OF THE SYSTEM FOR LMSMAs, SAs ACTING AS BALANCING PARTIES, AND LMSPAs and MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         Acadian/TGP Indian Bayou: Dip 510B- Delivery Meter (Pin 421056) - through 100% of SOP increases  due to pipeline maintenance at delivery location; 1,500 Dths

·         STA 823 (Segment 823 BH) - through approx 17% of SOP increases  due to nominations in excess of operational capacity; 4,021 Dths

·         STA 860 (Segment 860 BH) - through 100% of SOP increases  due to scheduled maintenance and emergent repair at STA 860; 21,215 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  due to operational concerns; 10 Dths

·         MLV 314 East (Segment 314 BH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 99,074 Dths

·         MLV 336 East (Segment 336 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 7,486 Dths

·         Z5HC North (Segment 299 FH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 308,288 Dths

·         STA 245 (Segment 245 FH) - through approx 72% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 111,548 Dths

·         Wright Receipt Meter (Pin 412181) - through approx 19% of SIPss delivery increases due to displacement gas unavailable for backhaul; 754 Dths

·         Agt/TGP Mendon Mass Tie Over Worche Delivery Meter (Pin 420285) - through approx 99% of IT receipt increases due to displacement gas unavailable for backhaul; 9,784 Dths

LINEPACK RESTRICTIONS

Payback to Tennessee will be evaluated at each cycle and scheduled if operationally feasible.  Parks and Loan Paybacks utilizing the PALD and PALAO services under the PAL Rate Schedule will be scheduled until further notice.

STORAGE RESTRICTIONS

Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field. 

 

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

 

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

..