Effective Intraday 2 Cycle (18:00) for the gas day of November 08, 2022 Tennessee restricted the following:
OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS
OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 0 (EXCLUDING AREAS SOUTH OF STA 1), L, 1, AND 2 FOR OVER-DELIVERIES INTO THE SYSTEM OR UNDER-TAKES OUT OF THE SYSTEM FOR LMSMAs, SAs ACTING AS BALANCING PARTIES, AND LMSPAs and MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM
RESTRICTIONS
· TGP/Php Sheridan Colorado Receipt Meter (Pin 54086) - through 100% of SOP increases due to operational concerns; 4,451 Dths
· MLV 509 (Segment 515 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 969 Dths
· Acadian/TGP Indian Bayou: Dip 510B- Delivery Meter (Pin 421056) - through 100% of SOP increases due to pipeline maintenance at delivery location; 1,500 Dths
· STA 823 (Segment 823 BH) - through 100% of SOP increases due to operational concerns; 25,000 Dths
· STA 860 (Segment 860 BH) - through 100% of SOP increases due to scheduled maintenance and emergent repair at STA 860; 851 Dths
· Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases due to operational concerns; 10 Dths
· TGP/SNG Pugh Mississippi Exch Lownd Delivery Meter (Pin 420294) - through approx 79% of SIPss increases due to nominations in excess of operational capacity; 3,122 Dths
· MLV 314 East (Segment 314 BH) - through approx 88% of SOP increases due to nominations in excess of operational capacity; 87,105 Dths
· STA 325 (Segment 324 FH) - through approx 89% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 75,460 Dths
· MLV 336 East (Segment 336 FH) - through 100% of SOP increases due to nominations in excess of operational capacity; 23,113 Dths
· Z5HC North (Segment 299 FH) - through approx 98% of SOP increases due to nominations in excess of operational capacity; 125,652 Dths
· STA 245 (Segment 245 FH) - through 100% of SOP increases due to scheduled maintenance and nominations in excess of operational capacity; 306,086 Dths
· Wright Receipt Meter (Pin 412181) - through 100% of SIPss delivery increases due to displacement gas unavailable for backhaul; 1,000 Dths
LINEPACK RESTRICTIONS
Payback to Tennessee will be evaluated at each cycle and scheduled if operationally feasible. Parks and Loan Paybacks utilizing the PALD and PALAO services under the PAL Rate Schedule will be scheduled until further notice.
STORAGE RESTRICTIONS
Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field.
Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice. Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.
**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.
**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.
If you have any questions, please contact your Scheduler.