Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  11/06/2022 7:16:20PM Notice End Date/Time:  11/07/2022 9:00:00am
Post Date/Time:  11/6/2022 7:16:20 PM Notice ID: 384882
Reqrd Rsp:  1 Rsp Date:  11/06/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 11-07-2022 EC
Notice Text:

Effective Evening Cycle (9:00) for the gas day of November 07, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

OFO DAILY CRITICAL DAY 1 FOR ALL OF ZONES 0 (EXCLUDING AREAS SOUTH OF STA 1), L, 1, 2, 3, 4, 5 AND 6 FOR OVER-DELIVERIES INTO THE SYSTEM OR UNDER-TAKES OUT OF THE SYSTEM FOR LMSMAs, SAs ACTING AS BALANCING PARTIES, AND LMSPAs and MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         Whistlep/TGP Whistler Receipt Nuece Receipt Meter (Pin 54847) - through 100% of SA increases  due to nominations in excess of operational capacity; 22,826 Dths

·         Cproc/TGP Hcp Colorado Receipt Meter (Pin 410144) - through 100% of SA increases  due to operational concerns; 2,570 Dths

·         TGP/Php Sheridan Colorado Receipt Meter (Pin 54086) - through 100% of SA increases  due to operational concerns; 15,420 Dths

·         MLV 509 (Segment 515 FH) - through 100% of SA increases  due to scheduled maintenance and nominations in excess of operational capacity; 11,012 Dths

·         STA 823 (Segment 823 BH) - through 100% of SOP increases  due to nominations in excess of operational capacity; 26,590 Dths

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 90% of SOP increases  due to imbalance management quantity exceeded; 163,383 Dths

·         STA 834 (Segment 834 BH) - through approx 85% of SOP increases  due to nominations in excess of operational capacity; 20,848 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  due to operational concerns; 10 Dths

·         STA 860 South 500 Line (Segment 548 BH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 5,000 Dths

·         Atmos Ky/TGP Danville Ky Boyle Delivery Meter (Pin 400462) - through approx 2% of SOP increases  due to nominations in excess of operational capacity; 300 Dths

·         STA 110 South (Segment 187 BH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 93,995 Dths

·         MLV 314 East (Segment 314 BH) - through approx 56% of SOP increases  due to nominations in excess of operational capacity; 12,797 Dths

·         STA 315 (Segment 315 BH) - through approx 90% of SOP increases  due to nominations in excess of operational capacity; 282,996 Dths

·         STA 321 (Segment 321 FH) - through approx 38% of SOP increases  due to nominations in excess of operational capacity; 78,053 Dths

·         Z5HC North (Segment 299 FH) - through approx 98% of SOP increases  due to nominations in excess of operational capacity; 212,962 Dths

·         STA 245 (Segment 245 FH) - through approx 78% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 177,361 Dths

·         Wright Delivery Meter (Pin 412181) - through 100% of SIPss increases deliveries due to displacement gas unavailable for backhaul; 3,000 Dths

·         MLV 273 (Segment 284 FH) - through approx 19% of SOP increases  due to nominations in excess of operational capacity; 3,487 Dths

LINEPACK RESTRICTIONS

Payback to Tennessee will be evaluated at each cycle and scheduled if operationally feasible.  Parks and Loan Paybacks utilizing the PALD and PALAO services under the PAL Rate Schedule will be scheduled until further notice.

STORAGE RESTRICTIONS

Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field. 

 

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

 

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

.