Notice Detail
           
Return To Results
TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  10/22/2022 3:01:03PM Notice End Date/Time:  10/23/2022 9:00:00am
Post Date/Time:  10/22/2022 3:01:03 PM Notice ID: 384714
Reqrd Rsp:  1 Rsp Date:  10/22/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 10-23-2022 TIMELY CYCLE
Notice Text:

Effective Timely Cycle (9:00) for the gas day of October 23, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM and IMBALANCE WARNING SYSTEM WIDE FOR LONGS

RESTRICTIONS

·         Net Mexi/TGP Gillrina Road Nueces Receipt Meter (Pin 47799) - through 100% of SA  due to operational concerns; 23,900 Dths

·         STA 823 (Segment 823 BH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 37,000 Dths

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 65% of SOP  due to imbalance management quantity exceeded; 169,934 Dths

·         STA 834 (Segment 834 BH) - through approx 63% of SOP  due to nominations in excess of operational capacity; 140,764 Dths

·         TGP/SNG Toca Exchange St Bernard Delivery Meter (Pin 420556) - through approx 99% of SOP  due to nominations in excess of operational capacity; 19,737 Dths

·         Gulfsth/TGP Petal Storage Field For Delivery Meter (Pin 420797) - through approx 10% of SIPps  due to imbalance management quantity exceeded; 7,451 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps  due to operational concerns; 10 Dths

·         TGP/SNG Rose Hill Miss Clarke Delivery Meter (Pin 420546) - through approx 28% of SIPps  due to nominations in excess of operational capacity; 115,796 Dths

·         MLV 548 (Segment 542 BH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 8,087 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP  due to force majeure at MLV 309 to MLV 310; 130,000 Dths

·         MLV 314 East (Segment 314 BH) - through approx 82% of SOP  due to nominations in excess of operational capacity; 119,355 Dths

·         STA 315 (Segment 315 BH) - through approx 93% of SOP  due to nominations in excess of operational capacity; 798,476 Dths

·         STA 321 (Segment 321 FH) - through approx 48% of SOP  due to nominations in excess of operational capacity; 356,773 Dths

·         Agt/TGP Mahwah New Jersey Bergen Delivery Meter (Pin 420207) - through approx 10% of SOP  due to nominations in excess of operational capacity; 8,102 Dths

·         MLV 336 East (Segment 336 FH) - through 100% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 40,000 Dths

·         Z5HC North (Segment 299 FH) - through approx 70% of SOP  due to nominations in excess of operational capacity; 567,230 Dths

·         STA 245 (Segment 245 FH) - through approx 90% of SOP  due to scheduled maintenance and nominations in excess of operational capacity; 605,907 Dths

·         MLV 273 (Segment 284 FH) - through approx 94% of SOP  due to nominations in excess of operational capacity; 211,889 Dths

LINEPACK RESTRICTIONS

Payback system wide TO the system will not be scheduled until further notice.  Additionally, PARKS and LOAN PAYBACKS TO the system utilizing PALD or PALAO services will not be scheduled until further notice.

STORAGE RESTRICTIONS

Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field. 

 

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

 

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.

If you have any questions, please contact your Scheduler.

 

..