TSP/TSP Name:  1939164-TENNESSEE GAS PIPELINE Critical: Y
Notice Type Desc (1):  PIPELINE CONDITIONS Notice Type Desc (2):  CURRENT PIPELINE CONDITIONS
Notice Eff Date/Time:  10/21/2022 3:17:47PM Notice End Date/Time:  10/22/2022 9:00:00am
Post Date/Time:  10/21/2022 3:17:47 PM Notice ID: 384707
Reqrd Rsp:  1 Rsp Date:  10/21/2022
Notice Stat Desc:  INITIATE Prior Notice: 
Subject:  RESTRICTIONS FOR 10-21-2022 ID2
Notice Text:

Effective Intraday 2 Cycle (18:00) for the gas day of October 21, 2022 Tennessee restricted the following:

OPERATIONAL FLOW ORDERS (OFO) AND IMBALANCE WARNINGS

MONTHLY OFO CRITICAL DAY 1 FOR ZONE 4 FOR ALL LMS-PA AND SA BALANCING PARTIES FOR OVER-DELIVERIES INTO THE SYSTEM

RESTRICTIONS

·         STA 823 (Segment 823 BH) - through 100% of SOP increases  due to operational concerns; 33,225 Dths

·         Pine Pra/TGP Pine Prairie North Rap Delivery Meter (Pin 421043) - through approx 81% of SOP increases  due to imbalance management quantity exceeded; 117,919 Dths

·         STA 834 (Segment 834 BH) - through approx 97% of SOP increases  due to nominations in excess of operational capacity; 37,697 Dths

·         Trnsco/TGP Heidelberg Missisippi Ja Delivery Meter (Pin 420291) - through 100% of SIPps increases  due to operational concerns; 10 Dths

·         Atmos Ky/TGP Harrodsburg Ky Boyle Delivery Meter (Pin 420028) - through 100% of SIPss increases  due to nominations in excess of operational capacity; 658 Dths

·         STA 110 South (Segment 187 BH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 2,040 Dths

·         STA 307 (Segment 307 BH) - through 100% of SOP increases  due to force majeure at MLV 309 to MLV 310; 55,000 Dths

·         MLV 314 East (Segment 314 BH) - through approx 86% of SOP increases  due to nominations in excess of operational capacity; 74,617 Dths

·         STA 315 (Segment 315 BH) - through approx 24% of SOP increases  due to nominations in excess of operational capacity; 26,302 Dths

·         STA 224 (Segment 224 FH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 15,030 Dths

·         STA 245 (Segment 245 FH) - through 100% of SOP increases  due to scheduled maintenance and nominations in excess of operational capacity; 186,327 Dths

·         MLV 273 (Segment 284 FH) - through approx 67% of SOP increases  due to nominations in excess of operational capacity; 26,821 Dths

LINEPACK RESTRICTIONS

Payback system wide will continue to be evaluated at each cycle and scheduled only if operationally feasible.

STORAGE RESTRICTIONS

Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-MA) at the Northern MA (460018) storage field and Tennessee will not accept nominations for Interruptible Storage Injection Services under Rate Schedule IS (IS-PA) at the Bear Creek PA (460017) storage field. 

 

Tennessee will NOT approve any transfers from accounts at TGP Bear Creek Storage to SNG Bear Creek Storage (460017)(IS-PA, FS-PA) until further notice.  Transfers into TGP Bear Creek Storage (460017) from SNG Bear Creek Storage will be allowed under the FS-PA storage service only with partner approvals.

 

 

 

**PLEASE NOTE THAT FINAL VOLUMES MAY CHANGE DUE TO SYSTEM BALANCING AND/OR CONFIRMATION REDUCTIONS.

**THE OUTAGE AND MAINTENANCE SCHEDULE IS AVAILABLE IN EXCEL SPREADSHEET AND ADOBE FORMATS WHICH MAY BE ACCESSED VIA A HYPERLINK UNDER NOTICES/PLANNED SERVICE OUTAGES.